{"title":"早期流光发射与传统防雷系统","authors":"Mladen S. Banjanin, Svetozar Banjanin","doi":"10.2478/bhee-2019-0003","DOIUrl":null,"url":null,"abstract":"Abstract This paper analyses and compares the conventional lightning protection systems proposed in IEC 62305 to the lightning protection systems based on the application of early streamer emission lightning rods proposed in NF C 17-102. Comparison between the two approaches to the lightning protection of structures was presented, both from a technical and economic point of view. Some inconsistencies in the conventional air termination system design methods are pointed out. The critical attitude of the scientific community regarding the declared protection characteristics of the early streamer emission lightning rods is discussed.","PeriodicalId":236883,"journal":{"name":"B&H Electrical Engineering","volume":"71 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Early Streamer Emission Vs Conventional Lightning Protection Systems\",\"authors\":\"Mladen S. Banjanin, Svetozar Banjanin\",\"doi\":\"10.2478/bhee-2019-0003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract This paper analyses and compares the conventional lightning protection systems proposed in IEC 62305 to the lightning protection systems based on the application of early streamer emission lightning rods proposed in NF C 17-102. Comparison between the two approaches to the lightning protection of structures was presented, both from a technical and economic point of view. Some inconsistencies in the conventional air termination system design methods are pointed out. The critical attitude of the scientific community regarding the declared protection characteristics of the early streamer emission lightning rods is discussed.\",\"PeriodicalId\":236883,\"journal\":{\"name\":\"B&H Electrical Engineering\",\"volume\":\"71 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"B&H Electrical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/bhee-2019-0003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"B&H Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/bhee-2019-0003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
摘要
摘要本文分析比较了IEC 62305中提出的传统防雷系统与NF C 17-102中提出的基于早期流光发射避雷针应用的防雷系统。从技术和经济的角度对两种结构防雷方法进行了比较。指出了传统空端系统设计方法的不一致性。讨论了科学界对早期流光发射避雷针防护特性的批评态度。
Early Streamer Emission Vs Conventional Lightning Protection Systems
Abstract This paper analyses and compares the conventional lightning protection systems proposed in IEC 62305 to the lightning protection systems based on the application of early streamer emission lightning rods proposed in NF C 17-102. Comparison between the two approaches to the lightning protection of structures was presented, both from a technical and economic point of view. Some inconsistencies in the conventional air termination system design methods are pointed out. The critical attitude of the scientific community regarding the declared protection characteristics of the early streamer emission lightning rods is discussed.