{"title":"基于DROGI控制方法的多功能3P4W公用事业集成单级分布式发电系统","authors":"Ritesh Gupta, S. Ghatakchoudhuri","doi":"10.1109/GlobConPT57482.2022.9938332","DOIUrl":null,"url":null,"abstract":"This article shows a Three-Phase, Four-Wire (3P4W) AC mains supportive single-stage, Solar Photovoltaic-Battery Energy Storage-Voltage Source Converter (SPV-BES-VSC) based Distributed Energy Generation System (DEG) to accomplish multiple functions, is presented using Double Reduced Order Generalised Integrator (DROGI). DROGI based Current Control performs multi-tasking such as, power factor correction and eliminates zero sequence harmonic from the neutral wire. One of the ROGI functions is to produce the 50 Hz peak component from the distorted, balanced/unbalanced load current. The purpose of another ROGI is to generate a sinusoidal unit template for reference AC mains current, even if sag/swell occurs at the Point of Common Coupling (PCC). BES system is protected from overcharge/deep discharge by using a Energy Management System (EMS). The complete control algorithm is realised in MATLAB in Discrete Time Frame (DTF) using simulink and Sim Power System (SPS) toolboxes for different operating conditions. The Total Harmonic Distortion (THD) of AC mains current is noticed within 5% according to IEEE-519 and 929, respectively.","PeriodicalId":431406,"journal":{"name":"2022 IEEE Global Conference on Computing, Power and Communication Technologies (GlobConPT)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Multi-Functional, 3P4W Utility Integrated Single- Stage Distributed Generating System With DROGI Based Control Approach\",\"authors\":\"Ritesh Gupta, S. Ghatakchoudhuri\",\"doi\":\"10.1109/GlobConPT57482.2022.9938332\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article shows a Three-Phase, Four-Wire (3P4W) AC mains supportive single-stage, Solar Photovoltaic-Battery Energy Storage-Voltage Source Converter (SPV-BES-VSC) based Distributed Energy Generation System (DEG) to accomplish multiple functions, is presented using Double Reduced Order Generalised Integrator (DROGI). DROGI based Current Control performs multi-tasking such as, power factor correction and eliminates zero sequence harmonic from the neutral wire. One of the ROGI functions is to produce the 50 Hz peak component from the distorted, balanced/unbalanced load current. The purpose of another ROGI is to generate a sinusoidal unit template for reference AC mains current, even if sag/swell occurs at the Point of Common Coupling (PCC). BES system is protected from overcharge/deep discharge by using a Energy Management System (EMS). The complete control algorithm is realised in MATLAB in Discrete Time Frame (DTF) using simulink and Sim Power System (SPS) toolboxes for different operating conditions. The Total Harmonic Distortion (THD) of AC mains current is noticed within 5% according to IEEE-519 and 929, respectively.\",\"PeriodicalId\":431406,\"journal\":{\"name\":\"2022 IEEE Global Conference on Computing, Power and Communication Technologies (GlobConPT)\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE Global Conference on Computing, Power and Communication Technologies (GlobConPT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/GlobConPT57482.2022.9938332\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Global Conference on Computing, Power and Communication Technologies (GlobConPT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/GlobConPT57482.2022.9938332","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
本文介绍了一种基于双降阶广义积分器(DROGI)的分布式发电系统(DEG),该系统支持单级太阳能光伏-电池储能-电压源转换器(spv - es - vsc)的三相四线(3P4W)交流电源,可实现多种功能。基于DROGI的电流控制执行多任务,如功率因数校正和消除零线的零序谐波。ROGI的功能之一是从扭曲的、平衡的/不平衡的负载电流中产生50 Hz的峰值分量。另一个ROGI的目的是为参考交流电源电流生成正弦单元模板,即使在共耦合点(PCC)发生凹陷/膨胀。BES系统通过使用能量管理系统(EMS)来防止过充/深度放电。采用simulink和Sim Power System (SPS)工具箱,在MATLAB中实现了离散时间框架(DTF)下的完整控制算法。根据IEEE-519和ieee - 929,交流市电电流的总谐波失真(THD)在5%以内。
A Multi-Functional, 3P4W Utility Integrated Single- Stage Distributed Generating System With DROGI Based Control Approach
This article shows a Three-Phase, Four-Wire (3P4W) AC mains supportive single-stage, Solar Photovoltaic-Battery Energy Storage-Voltage Source Converter (SPV-BES-VSC) based Distributed Energy Generation System (DEG) to accomplish multiple functions, is presented using Double Reduced Order Generalised Integrator (DROGI). DROGI based Current Control performs multi-tasking such as, power factor correction and eliminates zero sequence harmonic from the neutral wire. One of the ROGI functions is to produce the 50 Hz peak component from the distorted, balanced/unbalanced load current. The purpose of another ROGI is to generate a sinusoidal unit template for reference AC mains current, even if sag/swell occurs at the Point of Common Coupling (PCC). BES system is protected from overcharge/deep discharge by using a Energy Management System (EMS). The complete control algorithm is realised in MATLAB in Discrete Time Frame (DTF) using simulink and Sim Power System (SPS) toolboxes for different operating conditions. The Total Harmonic Distortion (THD) of AC mains current is noticed within 5% according to IEEE-519 and 929, respectively.