水树生长在聚乙烯与直流电

E. Franke, E. Czekaj
{"title":"水树生长在聚乙烯与直流电","authors":"E. Franke, E. Czekaj","doi":"10.1109/CEIDP.1975.7736663","DOIUrl":null,"url":null,"abstract":"High voltage dc is applied to the center conductor of submarine telecommunication coaxial cables to power evenly spaced amplifiers.1 Typical systems installed thus far have powering voltages between 3 and 6 kV, with the outer conductor in contact with sea water. Although no problems with tree growth in the polyethylene insulation have been encountered, new systems presently planned will require higher terminal voltages. In order to ensure the continued high reliability of submarine cable systems, an investigation of possible water tree growth in the polyethylene cabe core was initiated. It had been assumed that water trees do not grow with direct current.2,3 Based on our initial experiments, it appears that water trees do indeed initiate and grow with dc electrical stress, but at a much slower rate than with ac.","PeriodicalId":121906,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena - Annual Report 1975","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1975-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Water tree growth in polyethylene with direct current\",\"authors\":\"E. Franke, E. Czekaj\",\"doi\":\"10.1109/CEIDP.1975.7736663\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High voltage dc is applied to the center conductor of submarine telecommunication coaxial cables to power evenly spaced amplifiers.1 Typical systems installed thus far have powering voltages between 3 and 6 kV, with the outer conductor in contact with sea water. Although no problems with tree growth in the polyethylene insulation have been encountered, new systems presently planned will require higher terminal voltages. In order to ensure the continued high reliability of submarine cable systems, an investigation of possible water tree growth in the polyethylene cabe core was initiated. It had been assumed that water trees do not grow with direct current.2,3 Based on our initial experiments, it appears that water trees do indeed initiate and grow with dc electrical stress, but at a much slower rate than with ac.\",\"PeriodicalId\":121906,\"journal\":{\"name\":\"Conference on Electrical Insulation & Dielectric Phenomena - Annual Report 1975\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1975-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference on Electrical Insulation & Dielectric Phenomena - Annual Report 1975\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.1975.7736663\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference on Electrical Insulation & Dielectric Phenomena - Annual Report 1975","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1975.7736663","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

在海底通信同轴电缆的中心导体上施加高压直流电,为等间距放大器供电到目前为止安装的典型系统的供电电压在3到6千伏之间,外部导体与海水接触。尽管聚乙烯绝缘材料中没有树木生长的问题,但目前计划的新系统将需要更高的终端电压。为了确保海底电缆系统的持续高可靠性,对聚乙烯电缆芯中可能存在的水树生长进行了调查。人们一直认为水树不随直流电生长。根据我们最初的实验,水树似乎确实在直流电胁迫下启动和生长,但速度比交流电胁迫慢得多。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Water tree growth in polyethylene with direct current
High voltage dc is applied to the center conductor of submarine telecommunication coaxial cables to power evenly spaced amplifiers.1 Typical systems installed thus far have powering voltages between 3 and 6 kV, with the outer conductor in contact with sea water. Although no problems with tree growth in the polyethylene insulation have been encountered, new systems presently planned will require higher terminal voltages. In order to ensure the continued high reliability of submarine cable systems, an investigation of possible water tree growth in the polyethylene cabe core was initiated. It had been assumed that water trees do not grow with direct current.2,3 Based on our initial experiments, it appears that water trees do indeed initiate and grow with dc electrical stress, but at a much slower rate than with ac.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信