K. Kadowski, Y. Maeda, S. Kanahara, I. Kitani, S. Kiyohara, T. Ohta, S. Mitsuya
{"title":"极性反转电压脉冲作用下环氧块体中树形生长的空间电荷效应","authors":"K. Kadowski, Y. Maeda, S. Kanahara, I. Kitani, S. Kiyohara, T. Ohta, S. Mitsuya","doi":"10.1109/ISEIM.2008.4664523","DOIUrl":null,"url":null,"abstract":"This paper presents an experimental study on electrical tree propagation from a point electrode in an epoxy block subjected to polarity-reversed repetitive pulses after dc prestress. When the epoxy block at one end of a long coaxial cable is charged by a dc prestress and then directly grounded by closing a switch at the other end of the cable without any resistance, repetitive voltage pulses are applied to the epoxy block with a change in its polarity. In test for polarity-reversed tree with -dc prestress, tree length tends to be shorter than that for an positive impulse tree without prestress. However, the shape of the polarity-reversed tree becomes more busy. In test for polarity reversed tree with +dc prestress, tree length at room temperature is very short for both the pulses with and without the prestress because of the poor propagation capability in negative streamer. However, polarity-reversed tree at 120degC is very large because the negative streamer propagation is followed by the successive positive streamer caused by the second polarity reversal.","PeriodicalId":158811,"journal":{"name":"2008 International Symposium on Electrical Insulating Materials (ISEIM 2008)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Space charge effect on tree propagation in epoxy block subjected to polarity-reversed voltage pulses\",\"authors\":\"K. Kadowski, Y. Maeda, S. Kanahara, I. Kitani, S. Kiyohara, T. Ohta, S. Mitsuya\",\"doi\":\"10.1109/ISEIM.2008.4664523\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an experimental study on electrical tree propagation from a point electrode in an epoxy block subjected to polarity-reversed repetitive pulses after dc prestress. When the epoxy block at one end of a long coaxial cable is charged by a dc prestress and then directly grounded by closing a switch at the other end of the cable without any resistance, repetitive voltage pulses are applied to the epoxy block with a change in its polarity. In test for polarity-reversed tree with -dc prestress, tree length tends to be shorter than that for an positive impulse tree without prestress. However, the shape of the polarity-reversed tree becomes more busy. In test for polarity reversed tree with +dc prestress, tree length at room temperature is very short for both the pulses with and without the prestress because of the poor propagation capability in negative streamer. However, polarity-reversed tree at 120degC is very large because the negative streamer propagation is followed by the successive positive streamer caused by the second polarity reversal.\",\"PeriodicalId\":158811,\"journal\":{\"name\":\"2008 International Symposium on Electrical Insulating Materials (ISEIM 2008)\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 International Symposium on Electrical Insulating Materials (ISEIM 2008)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEIM.2008.4664523\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 International Symposium on Electrical Insulating Materials (ISEIM 2008)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEIM.2008.4664523","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Space charge effect on tree propagation in epoxy block subjected to polarity-reversed voltage pulses
This paper presents an experimental study on electrical tree propagation from a point electrode in an epoxy block subjected to polarity-reversed repetitive pulses after dc prestress. When the epoxy block at one end of a long coaxial cable is charged by a dc prestress and then directly grounded by closing a switch at the other end of the cable without any resistance, repetitive voltage pulses are applied to the epoxy block with a change in its polarity. In test for polarity-reversed tree with -dc prestress, tree length tends to be shorter than that for an positive impulse tree without prestress. However, the shape of the polarity-reversed tree becomes more busy. In test for polarity reversed tree with +dc prestress, tree length at room temperature is very short for both the pulses with and without the prestress because of the poor propagation capability in negative streamer. However, polarity-reversed tree at 120degC is very large because the negative streamer propagation is followed by the successive positive streamer caused by the second polarity reversal.