光伏并网逆变器正常与故障工况的设计与分析

M. Krishnan, R. Ramaprabha
{"title":"光伏并网逆变器正常与故障工况的设计与分析","authors":"M. Krishnan, R. Ramaprabha","doi":"10.1109/ICEES.2016.7510652","DOIUrl":null,"url":null,"abstract":"As there is a power shortage across any country, usage of renewable energy sources is being encouraged nowadays. This energy produced has to be properly synchronized with the grid to ensure safety and energy continuity. In this paper, a step by step procedure for designing a MPPT algorithm based photovoltaic (PV) generation system is presented. Moreover, the standard procedure for grid interconnection of inverter is discussed. The developed system feeds a common load, as the micro grid systems feeds the local loads. The system takes care of all the specified guidelines while feeding the load and is compared with the IEC 61727 standards, which discuss the current harmonic limit for a grid tie inverter.","PeriodicalId":308604,"journal":{"name":"2016 3rd International Conference on Electrical Energy Systems (ICEES)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Design and analysis of grid connected photovoltaic inverter under normal and fault conditions\",\"authors\":\"M. Krishnan, R. Ramaprabha\",\"doi\":\"10.1109/ICEES.2016.7510652\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As there is a power shortage across any country, usage of renewable energy sources is being encouraged nowadays. This energy produced has to be properly synchronized with the grid to ensure safety and energy continuity. In this paper, a step by step procedure for designing a MPPT algorithm based photovoltaic (PV) generation system is presented. Moreover, the standard procedure for grid interconnection of inverter is discussed. The developed system feeds a common load, as the micro grid systems feeds the local loads. The system takes care of all the specified guidelines while feeding the load and is compared with the IEC 61727 standards, which discuss the current harmonic limit for a grid tie inverter.\",\"PeriodicalId\":308604,\"journal\":{\"name\":\"2016 3rd International Conference on Electrical Energy Systems (ICEES)\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-03-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 3rd International Conference on Electrical Energy Systems (ICEES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEES.2016.7510652\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 3rd International Conference on Electrical Energy Systems (ICEES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEES.2016.7510652","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

由于任何国家都存在电力短缺,因此现在鼓励使用可再生能源。生产的能源必须与电网适当同步,以确保安全和能源连续性。提出了一种基于MPPT算法的光伏发电系统的分步设计方法。此外,还讨论了逆变器并网的标准程序。开发的系统馈入共同负荷,微网系统馈入局部负荷。该系统在馈电负载时满足所有规定的准则,并与IEC 61727标准进行了比较,IEC 61727标准讨论了并网逆变器的电流谐波限值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design and analysis of grid connected photovoltaic inverter under normal and fault conditions
As there is a power shortage across any country, usage of renewable energy sources is being encouraged nowadays. This energy produced has to be properly synchronized with the grid to ensure safety and energy continuity. In this paper, a step by step procedure for designing a MPPT algorithm based photovoltaic (PV) generation system is presented. Moreover, the standard procedure for grid interconnection of inverter is discussed. The developed system feeds a common load, as the micro grid systems feeds the local loads. The system takes care of all the specified guidelines while feeding the load and is compared with the IEC 61727 standards, which discuss the current harmonic limit for a grid tie inverter.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信