感应负载触点材料开关特性研究

Yubin He, Xu Zhang, W. Ren
{"title":"感应负载触点材料开关特性研究","authors":"Yubin He, Xu Zhang, W. Ren","doi":"10.1109/HLM51431.2021.9671176","DOIUrl":null,"url":null,"abstract":"Electrical performance and failure mechanisms of electromechanical relay for switching inductive load (such as motor or electromagnetic valve) are urgently demanded to know. In this work, the silver tin oxide contact material has been tested with a series of inductive load (1mH, 2mH, 3mH and 3.5mH) by using our designed novel model switch. The observed longer arcing duration and overload voltage results in the obvious material transfer features between contacts. The shrinkage of effective contact gap is the root reason for failing to break arc, which would lead to the final contact welding failure. Also, the observed sharp increment of arcing duration and contact force could be treated as the precursor of welding failure.","PeriodicalId":338653,"journal":{"name":"2021 IEEE 66th Holm Conference on Electrical Contacts (HLM)","volume":"121 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation of Switching Characteristics of Contact Materials for Inductive Load\",\"authors\":\"Yubin He, Xu Zhang, W. Ren\",\"doi\":\"10.1109/HLM51431.2021.9671176\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electrical performance and failure mechanisms of electromechanical relay for switching inductive load (such as motor or electromagnetic valve) are urgently demanded to know. In this work, the silver tin oxide contact material has been tested with a series of inductive load (1mH, 2mH, 3mH and 3.5mH) by using our designed novel model switch. The observed longer arcing duration and overload voltage results in the obvious material transfer features between contacts. The shrinkage of effective contact gap is the root reason for failing to break arc, which would lead to the final contact welding failure. Also, the observed sharp increment of arcing duration and contact force could be treated as the precursor of welding failure.\",\"PeriodicalId\":338653,\"journal\":{\"name\":\"2021 IEEE 66th Holm Conference on Electrical Contacts (HLM)\",\"volume\":\"121 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE 66th Holm Conference on Electrical Contacts (HLM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HLM51431.2021.9671176\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 66th Holm Conference on Electrical Contacts (HLM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HLM51431.2021.9671176","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

开关感性负载(如电机或电磁阀)的机电继电器的电气性能和失效机理迫切需要了解。在本工作中,利用我们设计的新型开关,对氧化银锡触点材料在1mH、2mH、3mH和3.5mH的一系列电感负载下进行了测试。电弧持续时间和过载电压较长导致触点之间的物质传递特征明显。有效接触间隙的收缩是断弧失败的根本原因,最终导致接触焊接失效。同时,观察到的电弧持续时间和接触力的急剧增加可视为焊接失效的前兆。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation of Switching Characteristics of Contact Materials for Inductive Load
Electrical performance and failure mechanisms of electromechanical relay for switching inductive load (such as motor or electromagnetic valve) are urgently demanded to know. In this work, the silver tin oxide contact material has been tested with a series of inductive load (1mH, 2mH, 3mH and 3.5mH) by using our designed novel model switch. The observed longer arcing duration and overload voltage results in the obvious material transfer features between contacts. The shrinkage of effective contact gap is the root reason for failing to break arc, which would lead to the final contact welding failure. Also, the observed sharp increment of arcing duration and contact force could be treated as the precursor of welding failure.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信