{"title":"VSC-MTDC混合直流断路器软重合闸模型","authors":"Ji Shu, Shunliang Wang, Tianqi Liu","doi":"10.1109/SPEC.2018.8636043","DOIUrl":null,"url":null,"abstract":"Using hybrid DC circuit breakers (HDCCB) to isolate faults in voltage source converter based multiterminal high voltage direct current (VSC-MTDC) system is a common fault protection solution. Many temporary faults would occur due to the use of long overhead lines, thus it's required to reclose HDCCB at the faulty line after fault is isolated and cleared. Over-current limiting is very important for the security and reliability of DC system during the reclosing process. A soft reclosing model (SRM) for HDCCB to limit the reclosing over-current is proposed in this paper. Operation procedure and detailed mathematical analysis are carried out to design circuit parameter of SRM. The proposed model is evaluated in a 5 terminal VSC-MTDC system. Compared to traditional reclosing method, this proposal can effectively limit the reclosing over-current to reduce the impact when reclosing on fault in DC system, thus the security and reliability of DC system can be improved.","PeriodicalId":335893,"journal":{"name":"2018 IEEE 4th Southern Power Electronics Conference (SPEC)","volume":"13 1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"A Soft Reclosing Model for Hybrid DC Circuit Breaker in VSC-MTDC System\",\"authors\":\"Ji Shu, Shunliang Wang, Tianqi Liu\",\"doi\":\"10.1109/SPEC.2018.8636043\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Using hybrid DC circuit breakers (HDCCB) to isolate faults in voltage source converter based multiterminal high voltage direct current (VSC-MTDC) system is a common fault protection solution. Many temporary faults would occur due to the use of long overhead lines, thus it's required to reclose HDCCB at the faulty line after fault is isolated and cleared. Over-current limiting is very important for the security and reliability of DC system during the reclosing process. A soft reclosing model (SRM) for HDCCB to limit the reclosing over-current is proposed in this paper. Operation procedure and detailed mathematical analysis are carried out to design circuit parameter of SRM. The proposed model is evaluated in a 5 terminal VSC-MTDC system. Compared to traditional reclosing method, this proposal can effectively limit the reclosing over-current to reduce the impact when reclosing on fault in DC system, thus the security and reliability of DC system can be improved.\",\"PeriodicalId\":335893,\"journal\":{\"name\":\"2018 IEEE 4th Southern Power Electronics Conference (SPEC)\",\"volume\":\"13 1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE 4th Southern Power Electronics Conference (SPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SPEC.2018.8636043\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE 4th Southern Power Electronics Conference (SPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPEC.2018.8636043","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

在基于电压源变换器的多端高压直流(vcs - mtdc)系统中,采用混合式直流断路器(HDCCB)隔离故障是一种常见的故障保护方案。由于使用较长的架空线,会发生许多临时故障,因此需要在故障隔离和清除后,在故障线上重新合闸HDCCB。过流限流对直流系统在重合闸过程中的安全性和可靠性至关重要。提出了一种限制HDCCB重合闸过电流的软重合闸模型(SRM)。对SRM的电路参数进行了详细的数学分析和操作程序设计。在5终端VSC-MTDC系统中对该模型进行了验证。与传统的重合闸方法相比,该方案可以有效地限制重合闸过电流,降低直流系统重合闸时对故障的影响,从而提高直流系统的安全性和可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Soft Reclosing Model for Hybrid DC Circuit Breaker in VSC-MTDC System
Using hybrid DC circuit breakers (HDCCB) to isolate faults in voltage source converter based multiterminal high voltage direct current (VSC-MTDC) system is a common fault protection solution. Many temporary faults would occur due to the use of long overhead lines, thus it's required to reclose HDCCB at the faulty line after fault is isolated and cleared. Over-current limiting is very important for the security and reliability of DC system during the reclosing process. A soft reclosing model (SRM) for HDCCB to limit the reclosing over-current is proposed in this paper. Operation procedure and detailed mathematical analysis are carried out to design circuit parameter of SRM. The proposed model is evaluated in a 5 terminal VSC-MTDC system. Compared to traditional reclosing method, this proposal can effectively limit the reclosing over-current to reduce the impact when reclosing on fault in DC system, thus the security and reliability of DC system can be improved.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信