电压参考电压矢量控制感应电动机驱动的自调试

F. Barrero, J. Pérez, R. Millán, L. Franquelo
{"title":"电压参考电压矢量控制感应电动机驱动的自调试","authors":"F. Barrero, J. Pérez, R. Millán, L. Franquelo","doi":"10.1109/IECON.1999.819350","DOIUrl":null,"url":null,"abstract":"This paper describes an automated self commissioning procedure for voltage referenced voltage fed vector controlled induction motor drives. A method for off-line determination of machine electrical parameters is presented. The measurement of the motor electrical variables at standstill time-domain test is used as an identification procedure base. Experimental results achieved with a 10 HP induction motor drive show good agreement between estimated and nominal electrical parameters. The proposed strategy is compared with other identification mechanisms, previously described in the literature, that have been improved with a proposed off-line current-dependent /spl sigma/L/sub s/ adaptation mechanism to obtain better accuracy. Results show similar behaviour using both identification schemes although the proposed scheme requires simpler tests.","PeriodicalId":378710,"journal":{"name":"IECON'99. Conference Proceedings. 25th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.99CH37029)","volume":"10 1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Self-commissioning for voltage-referenced voltage-fed vector controlled induction motor drives\",\"authors\":\"F. Barrero, J. Pérez, R. Millán, L. Franquelo\",\"doi\":\"10.1109/IECON.1999.819350\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes an automated self commissioning procedure for voltage referenced voltage fed vector controlled induction motor drives. A method for off-line determination of machine electrical parameters is presented. The measurement of the motor electrical variables at standstill time-domain test is used as an identification procedure base. Experimental results achieved with a 10 HP induction motor drive show good agreement between estimated and nominal electrical parameters. The proposed strategy is compared with other identification mechanisms, previously described in the literature, that have been improved with a proposed off-line current-dependent /spl sigma/L/sub s/ adaptation mechanism to obtain better accuracy. Results show similar behaviour using both identification schemes although the proposed scheme requires simpler tests.\",\"PeriodicalId\":378710,\"journal\":{\"name\":\"IECON'99. Conference Proceedings. 25th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.99CH37029)\",\"volume\":\"10 1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-11-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IECON'99. Conference Proceedings. 25th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.99CH37029)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON.1999.819350\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON'99. Conference Proceedings. 25th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.99CH37029)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.1999.819350","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本文介绍了一种电压参考电压矢量控制异步电动机驱动的自动自调试程序。提出了一种离线确定电机电气参数的方法。采用静止状态下电机电变量的时域测试作为识别程序的基础。用10马力感应电机驱动的实验结果表明,估计的电气参数与标称的电气参数吻合良好。将该策略与文献中描述的其他识别机制进行了比较,这些识别机制已经通过提出的离线电流依赖/spl sigma/L/sub s/自适应机制进行了改进,以获得更好的准确性。结果显示相似的行为使用两种识别方案,虽然所提出的方案需要更简单的测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Self-commissioning for voltage-referenced voltage-fed vector controlled induction motor drives
This paper describes an automated self commissioning procedure for voltage referenced voltage fed vector controlled induction motor drives. A method for off-line determination of machine electrical parameters is presented. The measurement of the motor electrical variables at standstill time-domain test is used as an identification procedure base. Experimental results achieved with a 10 HP induction motor drive show good agreement between estimated and nominal electrical parameters. The proposed strategy is compared with other identification mechanisms, previously described in the literature, that have been improved with a proposed off-line current-dependent /spl sigma/L/sub s/ adaptation mechanism to obtain better accuracy. Results show similar behaviour using both identification schemes although the proposed scheme requires simpler tests.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信