{"title":"转子故障下鼠笼式感应电机的精确模型","authors":"V. Devanneaux, H. Kabbaj, B. Dagues, J. Faucher","doi":"10.1109/ICEMS.2001.970693","DOIUrl":null,"url":null,"abstract":"A substantial portion of squirrel cage induction motor faults is rotor related. An accurate transient model of squirrel cage induction machines under rotor faults is presented. A coupled magnetic circuits approach is used and very few restrictive assumptions are made. All parameters are calculated from the actual geometry and winding layout of the machines rather than from transformed or equivalent variables. The detailed depiction of the procedure needed to implement such an accurate model with simulation results is the subject of this paper.","PeriodicalId":143007,"journal":{"name":"ICEMS'2001. Proceedings of the Fifth International Conference on Electrical Machines and Systems (IEEE Cat. No.01EX501)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"An accurate model of squirrel cage induction machines under rotor faults\",\"authors\":\"V. Devanneaux, H. Kabbaj, B. Dagues, J. Faucher\",\"doi\":\"10.1109/ICEMS.2001.970693\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A substantial portion of squirrel cage induction motor faults is rotor related. An accurate transient model of squirrel cage induction machines under rotor faults is presented. A coupled magnetic circuits approach is used and very few restrictive assumptions are made. All parameters are calculated from the actual geometry and winding layout of the machines rather than from transformed or equivalent variables. The detailed depiction of the procedure needed to implement such an accurate model with simulation results is the subject of this paper.\",\"PeriodicalId\":143007,\"journal\":{\"name\":\"ICEMS'2001. Proceedings of the Fifth International Conference on Electrical Machines and Systems (IEEE Cat. No.01EX501)\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-08-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ICEMS'2001. Proceedings of the Fifth International Conference on Electrical Machines and Systems (IEEE Cat. No.01EX501)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEMS.2001.970693\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICEMS'2001. Proceedings of the Fifth International Conference on Electrical Machines and Systems (IEEE Cat. No.01EX501)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEMS.2001.970693","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An accurate model of squirrel cage induction machines under rotor faults
A substantial portion of squirrel cage induction motor faults is rotor related. An accurate transient model of squirrel cage induction machines under rotor faults is presented. A coupled magnetic circuits approach is used and very few restrictive assumptions are made. All parameters are calculated from the actual geometry and winding layout of the machines rather than from transformed or equivalent variables. The detailed depiction of the procedure needed to implement such an accurate model with simulation results is the subject of this paper.