{"title":"氯气生产设备故障的评估","authors":"S. Andrew, R. Caligiuri, L. E. Eiselstein, T. K. Parnell","doi":"10.1115/imece2001/de-23297","DOIUrl":null,"url":null,"abstract":"\n A process upset at a chlorine production facility resulted in a release that forced the partial evacuation of a nearby town. Investigations revealed that the events commenced with the failure of a shell and tube heat exchanger (liquefier) used to condense chlorine gas. Post-incident inspections revealed a cloth at the liquefier coolant inlet that accelerated the flow in that region, causing certain tubes to be breached. As a result, the water-based brine liquefier coolant was entrained in the chlorine process stream, forming a highly acidic oxidizing mixture. This corrosive mixture then flowed to the chlorine storage tanks destroying an elbow in the tank inlet piping and rendering the tank shut-off tank valve ineffective, thus allowing chlorine to vent into the atmosphere.\n This paper discusses the multi-disciplinary approach used to investigate this incident. In particular, this paper discusses the detailed physical inspections performed, the finite element analyses used to determine the flow conditions, and the corrosion testing conducted to evaluate the failure.","PeriodicalId":197403,"journal":{"name":"Mechanical Engineering Design Education: Issues and Case Studies","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of a Failure in a Chlorine Production Facility\",\"authors\":\"S. Andrew, R. Caligiuri, L. E. Eiselstein, T. K. Parnell\",\"doi\":\"10.1115/imece2001/de-23297\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n A process upset at a chlorine production facility resulted in a release that forced the partial evacuation of a nearby town. Investigations revealed that the events commenced with the failure of a shell and tube heat exchanger (liquefier) used to condense chlorine gas. Post-incident inspections revealed a cloth at the liquefier coolant inlet that accelerated the flow in that region, causing certain tubes to be breached. As a result, the water-based brine liquefier coolant was entrained in the chlorine process stream, forming a highly acidic oxidizing mixture. This corrosive mixture then flowed to the chlorine storage tanks destroying an elbow in the tank inlet piping and rendering the tank shut-off tank valve ineffective, thus allowing chlorine to vent into the atmosphere.\\n This paper discusses the multi-disciplinary approach used to investigate this incident. In particular, this paper discusses the detailed physical inspections performed, the finite element analyses used to determine the flow conditions, and the corrosion testing conducted to evaluate the failure.\",\"PeriodicalId\":197403,\"journal\":{\"name\":\"Mechanical Engineering Design Education: Issues and Case Studies\",\"volume\":\"51 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Mechanical Engineering Design Education: Issues and Case Studies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/imece2001/de-23297\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mechanical Engineering Design Education: Issues and Case Studies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/imece2001/de-23297","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

氯气生产设施的一个过程发生故障,导致泄漏,迫使附近城镇的部分居民撤离。调查显示,事故起因是用于冷凝氯气的管壳式热交换器(液化器)发生故障。事故发生后的检查发现,液化器冷却剂进口处的一块布加速了该区域的流动,导致某些管道破裂。结果,水基卤水液化器冷却剂被夹带在氯工艺流中,形成高酸性氧化混合物。然后,这种腐蚀性混合物流入氯储罐,破坏了储罐入口管道中的弯头,使储罐关闭罐阀失效,从而使氯排放到大气中。本文讨论了用于调查这一事件的多学科方法。特别是,本文讨论了所进行的详细物理检查,用于确定流动条件的有限元分析以及用于评估失效的腐蚀测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of a Failure in a Chlorine Production Facility
A process upset at a chlorine production facility resulted in a release that forced the partial evacuation of a nearby town. Investigations revealed that the events commenced with the failure of a shell and tube heat exchanger (liquefier) used to condense chlorine gas. Post-incident inspections revealed a cloth at the liquefier coolant inlet that accelerated the flow in that region, causing certain tubes to be breached. As a result, the water-based brine liquefier coolant was entrained in the chlorine process stream, forming a highly acidic oxidizing mixture. This corrosive mixture then flowed to the chlorine storage tanks destroying an elbow in the tank inlet piping and rendering the tank shut-off tank valve ineffective, thus allowing chlorine to vent into the atmosphere. This paper discusses the multi-disciplinary approach used to investigate this incident. In particular, this paper discusses the detailed physical inspections performed, the finite element analyses used to determine the flow conditions, and the corrosion testing conducted to evaluate the failure.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信