低压控制策略对通信特性的实验灵敏度分析

Mario Faschang, R. Schwalbe, F. Kupzog
{"title":"低压控制策略对通信特性的实验灵敏度分析","authors":"Mario Faschang, R. Schwalbe, F. Kupzog","doi":"10.1109/PTC.2015.7232817","DOIUrl":null,"url":null,"abstract":"After the successful implementation of first smart grid solutions in the low voltage grids (like dynamic tap-changer switching or solar inverters' reactive and active power adaptation), the evaluation of their performance is of high interest. Due to the nature of the communication systems (e.g. narrow-band power-line communication), i.e. its highly varying message delay and potential packet loss, significant effects on distributed control systems can be expected. In this paper, we present an evaluation of the influence of varying communication channel parameters and the sensitivity of voltage control in distribution grids. Five test cases, together with a reference scenario are evaluated in co-simulation of a rural low voltage grid with high penetration of renewable energy resources. The sensitivity of the control system is assessed with a focus on EN50160 limitations. As results, insights on the sensitivity of novel low voltage grid control strategies are presented and recommendations for controller limit settings are given.","PeriodicalId":193448,"journal":{"name":"2015 IEEE Eindhoven PowerTech","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Experimental sensitivity analysis of low voltage control strategies on communication properties\",\"authors\":\"Mario Faschang, R. Schwalbe, F. Kupzog\",\"doi\":\"10.1109/PTC.2015.7232817\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"After the successful implementation of first smart grid solutions in the low voltage grids (like dynamic tap-changer switching or solar inverters' reactive and active power adaptation), the evaluation of their performance is of high interest. Due to the nature of the communication systems (e.g. narrow-band power-line communication), i.e. its highly varying message delay and potential packet loss, significant effects on distributed control systems can be expected. In this paper, we present an evaluation of the influence of varying communication channel parameters and the sensitivity of voltage control in distribution grids. Five test cases, together with a reference scenario are evaluated in co-simulation of a rural low voltage grid with high penetration of renewable energy resources. The sensitivity of the control system is assessed with a focus on EN50160 limitations. As results, insights on the sensitivity of novel low voltage grid control strategies are presented and recommendations for controller limit settings are given.\",\"PeriodicalId\":193448,\"journal\":{\"name\":\"2015 IEEE Eindhoven PowerTech\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Eindhoven PowerTech\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PTC.2015.7232817\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Eindhoven PowerTech","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PTC.2015.7232817","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

在低压电网中首次成功实施智能电网解决方案(如动态分接开关或太阳能逆变器的无功和有功自适应)后,对其性能的评估备受关注。由于通信系统的性质(例如窄带电力线通信),即其高度变化的消息延迟和潜在的数据包丢失,可以预期对分布式控制系统的重大影响。本文对配电网中不同通信信道参数和电压控制灵敏度的影响进行了评估。在可再生能源高渗透农村低压电网联合仿真中,对5个测试用例和参考场景进行了评估。对控制系统的灵敏度进行了评估,重点关注EN50160限制。结果,对新型低压电网控制策略的灵敏度提出了见解,并给出了控制器极限设置的建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental sensitivity analysis of low voltage control strategies on communication properties
After the successful implementation of first smart grid solutions in the low voltage grids (like dynamic tap-changer switching or solar inverters' reactive and active power adaptation), the evaluation of their performance is of high interest. Due to the nature of the communication systems (e.g. narrow-band power-line communication), i.e. its highly varying message delay and potential packet loss, significant effects on distributed control systems can be expected. In this paper, we present an evaluation of the influence of varying communication channel parameters and the sensitivity of voltage control in distribution grids. Five test cases, together with a reference scenario are evaluated in co-simulation of a rural low voltage grid with high penetration of renewable energy resources. The sensitivity of the control system is assessed with a focus on EN50160 limitations. As results, insights on the sensitivity of novel low voltage grid control strategies are presented and recommendations for controller limit settings are given.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信