串联式有源与并联无源滤波系统中终端电压总谐波失真的控制与降低

S. Bhattacharya, D. Divan, B. Banerjee
{"title":"串联式有源与并联无源滤波系统中终端电压总谐波失真的控制与降低","authors":"S. Bhattacharya, D. Divan, B. Banerjee","doi":"10.1109/PESC.1993.472012","DOIUrl":null,"url":null,"abstract":"A simple and cost-effective solution to reduce the passive filter terminal voltage total harmonic distortion (THD) is outlined. A modified synchronous reference frame (SRF) based controller for the series active filter allows injection of a controlled percentage of the higher harmonic load currents into the supply, in compliance with the IEEE 519 harmonic current standards, thereby reducing the passive filter terminal voltage THD. This implementation retains all the desirable features of the original SRF controlled hybrid series active filter system. It reduces the rating and size of the passive filter system and allows the use of simpler passive filter system structures such as only a simple high pass passive filter or a simple power factor correction capacitor as the passive filter system. Simulation and experimental results are used to establish the functionality and performance of the SRF controller and the modified SRF controller for the hybrid series active filter system.<<ETX>>","PeriodicalId":358822,"journal":{"name":"Proceedings of IEEE Power Electronics Specialist Conference - PESC '93","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"89","resultStr":"{\"title\":\"Control and reduction of terminal voltage total harmonic distortion (THD) in a hybrid series active and parallel passive filter system\",\"authors\":\"S. Bhattacharya, D. Divan, B. Banerjee\",\"doi\":\"10.1109/PESC.1993.472012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A simple and cost-effective solution to reduce the passive filter terminal voltage total harmonic distortion (THD) is outlined. A modified synchronous reference frame (SRF) based controller for the series active filter allows injection of a controlled percentage of the higher harmonic load currents into the supply, in compliance with the IEEE 519 harmonic current standards, thereby reducing the passive filter terminal voltage THD. This implementation retains all the desirable features of the original SRF controlled hybrid series active filter system. It reduces the rating and size of the passive filter system and allows the use of simpler passive filter system structures such as only a simple high pass passive filter or a simple power factor correction capacitor as the passive filter system. Simulation and experimental results are used to establish the functionality and performance of the SRF controller and the modified SRF controller for the hybrid series active filter system.<<ETX>>\",\"PeriodicalId\":358822,\"journal\":{\"name\":\"Proceedings of IEEE Power Electronics Specialist Conference - PESC '93\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-06-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"89\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of IEEE Power Electronics Specialist Conference - PESC '93\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESC.1993.472012\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of IEEE Power Electronics Specialist Conference - PESC '93","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1993.472012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 89

摘要

提出了一种降低无源滤波器终端电压总谐波失真(THD)的简单、经济的解决方案。一个改进的同步参考框架(SRF)为基础的串联有源滤波器控制器允许注入一个控制百分比的高谐波负载电流到电源中,符合IEEE 519谐波电流标准,从而降低无源滤波器终端电压THD。该实现保留了原始SRF控制混合串联有源滤波器系统的所有理想特性。它降低了无源滤波器系统的额定值和尺寸,并允许使用更简单的无源滤波器系统结构,例如仅使用简单的高通无源滤波器或简单的功率因数校正电容器作为无源滤波器系统。仿真和实验结果验证了SRF控制器和改进的SRF控制器在混合串联有源滤波系统中的功能和性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Control and reduction of terminal voltage total harmonic distortion (THD) in a hybrid series active and parallel passive filter system
A simple and cost-effective solution to reduce the passive filter terminal voltage total harmonic distortion (THD) is outlined. A modified synchronous reference frame (SRF) based controller for the series active filter allows injection of a controlled percentage of the higher harmonic load currents into the supply, in compliance with the IEEE 519 harmonic current standards, thereby reducing the passive filter terminal voltage THD. This implementation retains all the desirable features of the original SRF controlled hybrid series active filter system. It reduces the rating and size of the passive filter system and allows the use of simpler passive filter system structures such as only a simple high pass passive filter or a simple power factor correction capacitor as the passive filter system. Simulation and experimental results are used to establish the functionality and performance of the SRF controller and the modified SRF controller for the hybrid series active filter system.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信