加德满都与柏林光伏并网系统的对比研究

P. Karki, B. Adhikary, K. Sherpa
{"title":"加德满都与柏林光伏并网系统的对比研究","authors":"P. Karki, B. Adhikary, K. Sherpa","doi":"10.1109/ICSET.2012.6357397","DOIUrl":null,"url":null,"abstract":"The performance of solar photovoltaic cell depends on the geographical location and technology implemented to harness the available energy. Nepal is situated along the solar belt of 30° northern latitude and it is blessed with an average of 300 days of sunshine a year. Nevertheless, the total electric energy generated by different sources has been unable to meet the demand. So, including aforementioned facts, there are several reasons which advocate that Nepal has high potential to do research, develop and implement various photovoltaic technologies to generate additional solar energy to minimize the present energy crisis. This paper presents comparative analysis of grid-tied PV systems of Kathmandu and Berlin using PVsyst. The total amount of electric energy generated by PV arrays that can be fed into the grid and different losses that occur in the systems are analyzed and results are provided graphically.","PeriodicalId":256740,"journal":{"name":"2012 IEEE Third International Conference on Sustainable Energy Technologies (ICSET)","volume":"70 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"47","resultStr":"{\"title\":\"Comparative study of grid-tied photovoltaic (PV) system in Kathmandu and Berlin using PVsyst\",\"authors\":\"P. Karki, B. Adhikary, K. Sherpa\",\"doi\":\"10.1109/ICSET.2012.6357397\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The performance of solar photovoltaic cell depends on the geographical location and technology implemented to harness the available energy. Nepal is situated along the solar belt of 30° northern latitude and it is blessed with an average of 300 days of sunshine a year. Nevertheless, the total electric energy generated by different sources has been unable to meet the demand. So, including aforementioned facts, there are several reasons which advocate that Nepal has high potential to do research, develop and implement various photovoltaic technologies to generate additional solar energy to minimize the present energy crisis. This paper presents comparative analysis of grid-tied PV systems of Kathmandu and Berlin using PVsyst. The total amount of electric energy generated by PV arrays that can be fed into the grid and different losses that occur in the systems are analyzed and results are provided graphically.\",\"PeriodicalId\":256740,\"journal\":{\"name\":\"2012 IEEE Third International Conference on Sustainable Energy Technologies (ICSET)\",\"volume\":\"70 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"47\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE Third International Conference on Sustainable Energy Technologies (ICSET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSET.2012.6357397\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Third International Conference on Sustainable Energy Technologies (ICSET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSET.2012.6357397","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 47

摘要

太阳能光伏电池的性能取决于地理位置和利用可用能源的技术。尼泊尔位于北纬30°的太阳带,每年平均有300天的日照。然而,不同来源产生的总电能已经无法满足需求。因此,包括上述事实在内,有几个理由主张尼泊尔有很大的潜力进行研究,开发和实施各种光伏技术,以产生额外的太阳能,以尽量减少目前的能源危机。本文采用PVsyst对加德满都和柏林的并网光伏系统进行了对比分析。可以输入电网的PV阵列产生的电能总量和系统中发生的不同损失进行了分析,并以图形形式提供了结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative study of grid-tied photovoltaic (PV) system in Kathmandu and Berlin using PVsyst
The performance of solar photovoltaic cell depends on the geographical location and technology implemented to harness the available energy. Nepal is situated along the solar belt of 30° northern latitude and it is blessed with an average of 300 days of sunshine a year. Nevertheless, the total electric energy generated by different sources has been unable to meet the demand. So, including aforementioned facts, there are several reasons which advocate that Nepal has high potential to do research, develop and implement various photovoltaic technologies to generate additional solar energy to minimize the present energy crisis. This paper presents comparative analysis of grid-tied PV systems of Kathmandu and Berlin using PVsyst. The total amount of electric energy generated by PV arrays that can be fed into the grid and different losses that occur in the systems are analyzed and results are provided graphically.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信