电能质量与谐波负荷

K. Munasinghe, S. Abeyratne
{"title":"电能质量与谐波负荷","authors":"K. Munasinghe, S. Abeyratne","doi":"10.1109/ICIIS.2006.365634","DOIUrl":null,"url":null,"abstract":"This paper presents the results of a research done on the harmonic distortion of load current and voltage in low voltage distribution networks owing to the extensive use of peak-detecting type capacitor-filter rectifier systems (often the front-end of non linear electronic loads). A classical case to be studied is the compact fluorescent lamps (CFLs) without power factor correction being implemented. It has become evident that the use of CFLs alone is more or less accountable to the non-linear loads generated in rural electrification schemes in Sri Lanka. A case study was also done by the authors on a chosen low voltage distribution network to analyze the impact of CFL loads and the capabilities of the network with regard to IEEE 519 regulations. The methods of analysis and the results are presented in this paper and PSCAD software has been used to simulate the system. The commercial aspects of using CFLs and energy saving have been discussed. Harmonic effects on the distribution transformers are studied as applied to the line segment considered in the study","PeriodicalId":122994,"journal":{"name":"First International Conference on Industrial and Information Systems","volume":"106 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Power Quality And Harmonic Loads\",\"authors\":\"K. Munasinghe, S. Abeyratne\",\"doi\":\"10.1109/ICIIS.2006.365634\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the results of a research done on the harmonic distortion of load current and voltage in low voltage distribution networks owing to the extensive use of peak-detecting type capacitor-filter rectifier systems (often the front-end of non linear electronic loads). A classical case to be studied is the compact fluorescent lamps (CFLs) without power factor correction being implemented. It has become evident that the use of CFLs alone is more or less accountable to the non-linear loads generated in rural electrification schemes in Sri Lanka. A case study was also done by the authors on a chosen low voltage distribution network to analyze the impact of CFL loads and the capabilities of the network with regard to IEEE 519 regulations. The methods of analysis and the results are presented in this paper and PSCAD software has been used to simulate the system. The commercial aspects of using CFLs and energy saving have been discussed. Harmonic effects on the distribution transformers are studied as applied to the line segment considered in the study\",\"PeriodicalId\":122994,\"journal\":{\"name\":\"First International Conference on Industrial and Information Systems\",\"volume\":\"106 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"First International Conference on Industrial and Information Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIIS.2006.365634\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"First International Conference on Industrial and Information Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIIS.2006.365634","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

本文介绍了由于检峰型电容滤波整流系统(通常是非线性电子负载的前端)的广泛使用而引起的低压配电网中负载电流和电压谐波畸变的研究结果。要研究的一个经典案例是没有进行功率因数校正的紧凑型荧光灯(cfl)。很明显,仅使用节能灯就或多或少造成了斯里兰卡农村电气化计划中产生的非线性负荷。作者还对一个选定的低压配电网进行了案例研究,以分析CFL负载的影响以及该网络在IEEE 519法规方面的能力。本文给出了分析方法和结果,并利用PSCAD软件对系统进行了仿真。讨论了节能灯的商业应用和节能问题。应用所考虑的线段,对配电变压器的谐波效应进行了研究
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Power Quality And Harmonic Loads
This paper presents the results of a research done on the harmonic distortion of load current and voltage in low voltage distribution networks owing to the extensive use of peak-detecting type capacitor-filter rectifier systems (often the front-end of non linear electronic loads). A classical case to be studied is the compact fluorescent lamps (CFLs) without power factor correction being implemented. It has become evident that the use of CFLs alone is more or less accountable to the non-linear loads generated in rural electrification schemes in Sri Lanka. A case study was also done by the authors on a chosen low voltage distribution network to analyze the impact of CFL loads and the capabilities of the network with regard to IEEE 519 regulations. The methods of analysis and the results are presented in this paper and PSCAD software has been used to simulate the system. The commercial aspects of using CFLs and energy saving have been discussed. Harmonic effects on the distribution transformers are studied as applied to the line segment considered in the study
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信