{"title":"SOFIA导尿管经ADAPT和Solumbra技术用于急性缺血性卒中机械取栓的疗效和安全性:一项系统综述和荟萃分析。","authors":"M. Essibayi, W. Brinjikji","doi":"10.1177/15910199221107438","DOIUrl":null,"url":null,"abstract":"INTRODUCTION\nSOFIA catheter is a relatively new and recently FDA-approved aspiration catheter. This systematic review aims to investigate the safety and efficacy of SOFIA catheter for treatment of acute ischemic stroke (AIS) via ADAPT and Solumbra techniques.\n\n\nMETHODS\nSearch of all studies evaluating the SOFIA catheter for mechanical thrombectomy (MT) for treatment of AIS via ADAPT and Solumbra techniques from inception through 2020 on Pubmed, PMC, and Embase was performed. We analyzed the angiographic and clinical outcomes of both techniques with SOFIA catheter using the random-effects model.\n\n\nRESULTS\nFrom 18 studies, 1836 patients were included with 1365 receiving MT using ADAPT and 471 with solumbra technique. The mean age was 69.8 years and 51.1% of the patients were women. The rate of rescue therapy was 30%. The outcomes rates of ADAPT group were as follows; mFPE (59.3%), FPE (34.4%) final TICI 2b/3 (89.3%), procedural complications (8%), embolization to new territory (ENT) (2.3%), symptomatic ICH (5.4%), mean NIHSS (8.97), 90-day-mRS 0-2 (48.8%), and mortality (15.3%). The outcomes rates of Solumbra group were as follows; mFPE (60.5%), FPE (46.7%), final TICI 2b/3 (93%), procedural complications (6.4%), ENT (2%), symptomatic ICH (6%), mean NIHSS (7.59), mRS 0-2 (53.8%), and mortality (10.8%). ICA and posterior circulation strokes, and tandem lesions had worse outcomes (P < .005). MCA strokes were associated with better outcomes (P = .005). ASPECT scores' association with the clinical outcomes was found statistically significant.\n\n\nCONCLUSION\nSOFIA catheter is effective and safe to treat acute ischemic stroke regardless of applied MT technique.","PeriodicalId":126264,"journal":{"name":"Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences","volume":"86 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Efficacy and safety of SOFIA aspiration catheter for mechanical thrombectomy via ADAPT and Solumbra echniques in acute ischemic stroke: A systematic review and meta-analysis.\",\"authors\":\"M. Essibayi, W. Brinjikji\",\"doi\":\"10.1177/15910199221107438\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"INTRODUCTION\\nSOFIA catheter is a relatively new and recently FDA-approved aspiration catheter. This systematic review aims to investigate the safety and efficacy of SOFIA catheter for treatment of acute ischemic stroke (AIS) via ADAPT and Solumbra techniques.\\n\\n\\nMETHODS\\nSearch of all studies evaluating the SOFIA catheter for mechanical thrombectomy (MT) for treatment of AIS via ADAPT and Solumbra techniques from inception through 2020 on Pubmed, PMC, and Embase was performed. We analyzed the angiographic and clinical outcomes of both techniques with SOFIA catheter using the random-effects model.\\n\\n\\nRESULTS\\nFrom 18 studies, 1836 patients were included with 1365 receiving MT using ADAPT and 471 with solumbra technique. The mean age was 69.8 years and 51.1% of the patients were women. The rate of rescue therapy was 30%. The outcomes rates of ADAPT group were as follows; mFPE (59.3%), FPE (34.4%) final TICI 2b/3 (89.3%), procedural complications (8%), embolization to new territory (ENT) (2.3%), symptomatic ICH (5.4%), mean NIHSS (8.97), 90-day-mRS 0-2 (48.8%), and mortality (15.3%). The outcomes rates of Solumbra group were as follows; mFPE (60.5%), FPE (46.7%), final TICI 2b/3 (93%), procedural complications (6.4%), ENT (2%), symptomatic ICH (6%), mean NIHSS (7.59), mRS 0-2 (53.8%), and mortality (10.8%). ICA and posterior circulation strokes, and tandem lesions had worse outcomes (P < .005). MCA strokes were associated with better outcomes (P = .005). ASPECT scores' association with the clinical outcomes was found statistically significant.\\n\\n\\nCONCLUSION\\nSOFIA catheter is effective and safe to treat acute ischemic stroke regardless of applied MT technique.\",\"PeriodicalId\":126264,\"journal\":{\"name\":\"Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences\",\"volume\":\"86 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/15910199221107438\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/15910199221107438","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Efficacy and safety of SOFIA aspiration catheter for mechanical thrombectomy via ADAPT and Solumbra echniques in acute ischemic stroke: A systematic review and meta-analysis.
INTRODUCTION
SOFIA catheter is a relatively new and recently FDA-approved aspiration catheter. This systematic review aims to investigate the safety and efficacy of SOFIA catheter for treatment of acute ischemic stroke (AIS) via ADAPT and Solumbra techniques.
METHODS
Search of all studies evaluating the SOFIA catheter for mechanical thrombectomy (MT) for treatment of AIS via ADAPT and Solumbra techniques from inception through 2020 on Pubmed, PMC, and Embase was performed. We analyzed the angiographic and clinical outcomes of both techniques with SOFIA catheter using the random-effects model.
RESULTS
From 18 studies, 1836 patients were included with 1365 receiving MT using ADAPT and 471 with solumbra technique. The mean age was 69.8 years and 51.1% of the patients were women. The rate of rescue therapy was 30%. The outcomes rates of ADAPT group were as follows; mFPE (59.3%), FPE (34.4%) final TICI 2b/3 (89.3%), procedural complications (8%), embolization to new territory (ENT) (2.3%), symptomatic ICH (5.4%), mean NIHSS (8.97), 90-day-mRS 0-2 (48.8%), and mortality (15.3%). The outcomes rates of Solumbra group were as follows; mFPE (60.5%), FPE (46.7%), final TICI 2b/3 (93%), procedural complications (6.4%), ENT (2%), symptomatic ICH (6%), mean NIHSS (7.59), mRS 0-2 (53.8%), and mortality (10.8%). ICA and posterior circulation strokes, and tandem lesions had worse outcomes (P < .005). MCA strokes were associated with better outcomes (P = .005). ASPECT scores' association with the clinical outcomes was found statistically significant.
CONCLUSION