{"title":"含双馈感应发电机的风能转换系统在变流器故障条件下的运行特性研究","authors":"D. Giaourakis, A. Safacas, S. Tsotoulidis","doi":"10.1109/ICIT.2012.6210081","DOIUrl":null,"url":null,"abstract":"In this paper, the wind energy conversion system that uses the structure of Doubly-Fed Induction Generator (DFIG) under fault condition is presented. Moreover, a simulation of this wind energy conversion system under fault conditions in MATLAB/SIMULINK is done and the results are evaluated. Two typical cases of fault, open-circuit faults in two IGBTs in Rotor Side Converter and in one diode in Grid Side Converter are studied.","PeriodicalId":365141,"journal":{"name":"2012 IEEE International Conference on Industrial Technology","volume":"335 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Investigation of the operational behaviour of a wind energy conversion system including double fed induction generator in converter's faulty conditions\",\"authors\":\"D. Giaourakis, A. Safacas, S. Tsotoulidis\",\"doi\":\"10.1109/ICIT.2012.6210081\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, the wind energy conversion system that uses the structure of Doubly-Fed Induction Generator (DFIG) under fault condition is presented. Moreover, a simulation of this wind energy conversion system under fault conditions in MATLAB/SIMULINK is done and the results are evaluated. Two typical cases of fault, open-circuit faults in two IGBTs in Rotor Side Converter and in one diode in Grid Side Converter are studied.\",\"PeriodicalId\":365141,\"journal\":{\"name\":\"2012 IEEE International Conference on Industrial Technology\",\"volume\":\"335 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-03-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE International Conference on Industrial Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIT.2012.6210081\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE International Conference on Industrial Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIT.2012.6210081","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Investigation of the operational behaviour of a wind energy conversion system including double fed induction generator in converter's faulty conditions
In this paper, the wind energy conversion system that uses the structure of Doubly-Fed Induction Generator (DFIG) under fault condition is presented. Moreover, a simulation of this wind energy conversion system under fault conditions in MATLAB/SIMULINK is done and the results are evaluated. Two typical cases of fault, open-circuit faults in two IGBTs in Rotor Side Converter and in one diode in Grid Side Converter are studied.