{"title":"利用日记录查找表技术的新型MPPT方法:占空比与温度的关系","authors":"Yuttikarn Lapkitticharoenchai, A. Jangwanitlert","doi":"10.1109/iceast55249.2022.9826330","DOIUrl":null,"url":null,"abstract":"This paper shows the new technique of tracking Maximum Power Point (MPP) that is faster than P&O one. Furthermore, it can reduce the swing of MPP but P&O technique never deal with. This technique uses automatically selective technique between P&O and Lookup Table to reach MPP. At first, the controller selects P&O technique to track MPP and record the data on relationship between temperature and duty cycle into the Table. When the data in the Table are more enough and the recent temperature value is under defined condition, the controller will change P&O to Lookup Table technique automatically. However, the recorded data in the Table will be reset every day for tracking MPP accurately.","PeriodicalId":441430,"journal":{"name":"2022 8th International Conference on Engineering, Applied Sciences, and Technology (ICEAST)","volume":"99 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Novel MPPT Methodology by using Daily Recorded Lookup Table Technique: Relationship between Duty Cycle and Temperature\",\"authors\":\"Yuttikarn Lapkitticharoenchai, A. Jangwanitlert\",\"doi\":\"10.1109/iceast55249.2022.9826330\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper shows the new technique of tracking Maximum Power Point (MPP) that is faster than P&O one. Furthermore, it can reduce the swing of MPP but P&O technique never deal with. This technique uses automatically selective technique between P&O and Lookup Table to reach MPP. At first, the controller selects P&O technique to track MPP and record the data on relationship between temperature and duty cycle into the Table. When the data in the Table are more enough and the recent temperature value is under defined condition, the controller will change P&O to Lookup Table technique automatically. However, the recorded data in the Table will be reset every day for tracking MPP accurately.\",\"PeriodicalId\":441430,\"journal\":{\"name\":\"2022 8th International Conference on Engineering, Applied Sciences, and Technology (ICEAST)\",\"volume\":\"99 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 8th International Conference on Engineering, Applied Sciences, and Technology (ICEAST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/iceast55249.2022.9826330\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 8th International Conference on Engineering, Applied Sciences, and Technology (ICEAST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/iceast55249.2022.9826330","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Novel MPPT Methodology by using Daily Recorded Lookup Table Technique: Relationship between Duty Cycle and Temperature
This paper shows the new technique of tracking Maximum Power Point (MPP) that is faster than P&O one. Furthermore, it can reduce the swing of MPP but P&O technique never deal with. This technique uses automatically selective technique between P&O and Lookup Table to reach MPP. At first, the controller selects P&O technique to track MPP and record the data on relationship between temperature and duty cycle into the Table. When the data in the Table are more enough and the recent temperature value is under defined condition, the controller will change P&O to Lookup Table technique automatically. However, the recorded data in the Table will be reset every day for tracking MPP accurately.