{"title":"基于差分进化的电力系统可观测性PMU优化配置","authors":"A. Al-Mohammed, M. Abido, M. Mansour","doi":"10.1109/ISDA.2011.6121668","DOIUrl":null,"url":null,"abstract":"This paper investigates the application of differential evolution (DE) algorithm for the problem of optimal placement of phasor measurement units (PMUs) in an electric power network. The problem is to determine the minimum number of PMUs and their respective locations to make the system observable. In order to cope with the continuous changes in the power system's topology, the optimization problem is formulated considering not only the new PMUs to be installed but also the existing ones to be retained or relocated. Additionally, the new formulation takes into account the locations, if any, at which PMUs shall or shall not be placed. The effectiveness of the proposed method is verified via IEEE 14-bus, 30-bus, 39-bus and 57-bus standard systems.","PeriodicalId":433207,"journal":{"name":"2011 11th International Conference on Intelligent Systems Design and Applications","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"26","resultStr":"{\"title\":\"Optimal PMU placement for power system observability using differential evolution\",\"authors\":\"A. Al-Mohammed, M. Abido, M. Mansour\",\"doi\":\"10.1109/ISDA.2011.6121668\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper investigates the application of differential evolution (DE) algorithm for the problem of optimal placement of phasor measurement units (PMUs) in an electric power network. The problem is to determine the minimum number of PMUs and their respective locations to make the system observable. In order to cope with the continuous changes in the power system's topology, the optimization problem is formulated considering not only the new PMUs to be installed but also the existing ones to be retained or relocated. Additionally, the new formulation takes into account the locations, if any, at which PMUs shall or shall not be placed. The effectiveness of the proposed method is verified via IEEE 14-bus, 30-bus, 39-bus and 57-bus standard systems.\",\"PeriodicalId\":433207,\"journal\":{\"name\":\"2011 11th International Conference on Intelligent Systems Design and Applications\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"26\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 11th International Conference on Intelligent Systems Design and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISDA.2011.6121668\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 11th International Conference on Intelligent Systems Design and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISDA.2011.6121668","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 26

摘要

研究了差分进化算法在电网相量测量单元(pmu)优化配置问题中的应用。问题是确定pmu的最小数量及其各自的位置,以使系统可观察。为了适应电力系统拓扑结构的不断变化,既考虑新安装的pmu,又考虑现有pmu的保留或搬迁,制定了优化问题。此外,新的表述考虑到pmu应该或不应该放置的位置(如果有的话)。通过IEEE 14总线、30总线、39总线和57总线标准系统验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimal PMU placement for power system observability using differential evolution
This paper investigates the application of differential evolution (DE) algorithm for the problem of optimal placement of phasor measurement units (PMUs) in an electric power network. The problem is to determine the minimum number of PMUs and their respective locations to make the system observable. In order to cope with the continuous changes in the power system's topology, the optimization problem is formulated considering not only the new PMUs to be installed but also the existing ones to be retained or relocated. Additionally, the new formulation takes into account the locations, if any, at which PMUs shall or shall not be placed. The effectiveness of the proposed method is verified via IEEE 14-bus, 30-bus, 39-bus and 57-bus standard systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信