基于电力线的局域网在住宅通信与控制中的应用

J. Kelly, C. J. Waters, E. Buffkin
{"title":"基于电力线的局域网在住宅通信与控制中的应用","authors":"J. Kelly, C. J. Waters, E. Buffkin","doi":"10.1109/CWLAN.1992.275720","DOIUrl":null,"url":null,"abstract":"Southern California Edison is currently developing a system level house design that allows one central intelligent unit to control a variety of domestic tasks which will enhance customer convenience, comfort, security, energy efficiency and management. One of the control and communications strategies under test uses the CEBus (consumer electronics bus) spread spectrum technology to transmit data and control signals over existing AC power lines. This report discusses the test program and current development status. Phase I is a large scale communication test performed during the spring and summer of 1992. This test evaluated the reliability of the CEBus communication protocol in actual occupied homes. Phase II is an appliance control test in which modified appliances were controlled and operational data collected using the CEBus. Test results for both phases are discussed.<<ETX>>","PeriodicalId":311143,"journal":{"name":"[1992] Proceedings IEEE Conference on Wireless LAN Implementation","volume":"141 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Power line based LAN applications in residential communications and control\",\"authors\":\"J. Kelly, C. J. Waters, E. Buffkin\",\"doi\":\"10.1109/CWLAN.1992.275720\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Southern California Edison is currently developing a system level house design that allows one central intelligent unit to control a variety of domestic tasks which will enhance customer convenience, comfort, security, energy efficiency and management. One of the control and communications strategies under test uses the CEBus (consumer electronics bus) spread spectrum technology to transmit data and control signals over existing AC power lines. This report discusses the test program and current development status. Phase I is a large scale communication test performed during the spring and summer of 1992. This test evaluated the reliability of the CEBus communication protocol in actual occupied homes. Phase II is an appliance control test in which modified appliances were controlled and operational data collected using the CEBus. Test results for both phases are discussed.<<ETX>>\",\"PeriodicalId\":311143,\"journal\":{\"name\":\"[1992] Proceedings IEEE Conference on Wireless LAN Implementation\",\"volume\":\"141 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-09-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"[1992] Proceedings IEEE Conference on Wireless LAN Implementation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CWLAN.1992.275720\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1992] Proceedings IEEE Conference on Wireless LAN Implementation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CWLAN.1992.275720","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

南加州爱迪生公司目前正在开发一种系统级房屋设计,允许一个中央智能单元控制各种家庭任务,这将提高客户的便利性、舒适性、安全性、能源效率和管理。测试中的控制和通信策略之一使用CEBus(消费电子总线)扩频技术在现有的交流电源线上传输数据和控制信号。本报告讨论了测试方案和目前的发展状况。第一阶段是1992年春季和夏季进行的一次大规模通讯试验。该测试评估了CEBus通信协议在实际占用房屋中的可靠性。阶段II是设备控制测试,其中使用CEBus控制修改的设备并收集操作数据。讨论了两阶段的试验结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Power line based LAN applications in residential communications and control
Southern California Edison is currently developing a system level house design that allows one central intelligent unit to control a variety of domestic tasks which will enhance customer convenience, comfort, security, energy efficiency and management. One of the control and communications strategies under test uses the CEBus (consumer electronics bus) spread spectrum technology to transmit data and control signals over existing AC power lines. This report discusses the test program and current development status. Phase I is a large scale communication test performed during the spring and summer of 1992. This test evaluated the reliability of the CEBus communication protocol in actual occupied homes. Phase II is an appliance control test in which modified appliances were controlled and operational data collected using the CEBus. Test results for both phases are discussed.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信