脑性麻痹儿童柔性双相功能电刺激器

Z. Hussain, Harith Firdaus Mustapha, E. Noorsal, K. A. Ahmad, K. Sooksood
{"title":"脑性麻痹儿童柔性双相功能电刺激器","authors":"Z. Hussain, Harith Firdaus Mustapha, E. Noorsal, K. A. Ahmad, K. Sooksood","doi":"10.1109/ICCSCE52189.2021.9530858","DOIUrl":null,"url":null,"abstract":"The functional electrical stimulator, FES has been extensively used for rehabilitation, however, in children with cerebral palsy, the need for a suitable FES device is vital. The current available FES device on the market is mostly not a robust and multifunction device. The need of flexible FES where the parameter that can be adjusted is very important to develop In this paper, a biphasic functional electrical stimulator (FES) has been designed and implemented.. The parameter that need to be controlled in a rehabilitation activity for children with cerebral palsy such as voltage, current, frequency and pulse width. The main parts in the design of the simple biphasic functional electrical stimulator are controller, a digital-to-analog converter, and a constant current source. The constant current source consists of a biphasic amplifier, summing amplifier and Howland pump charge circuit. The result show that the Functional Electrical Stimulator developed capable to meet with the performance of the stimulated design in Proteus and capable to achieved the desired output needed for rehabilitation for children with cerebral palsy.","PeriodicalId":285507,"journal":{"name":"2021 11th IEEE International Conference on Control System, Computing and Engineering (ICCSCE)","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Flexible Biphasic Functional Electrical Stimulator for Children with Cerebral Palsy\",\"authors\":\"Z. Hussain, Harith Firdaus Mustapha, E. Noorsal, K. A. Ahmad, K. Sooksood\",\"doi\":\"10.1109/ICCSCE52189.2021.9530858\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The functional electrical stimulator, FES has been extensively used for rehabilitation, however, in children with cerebral palsy, the need for a suitable FES device is vital. The current available FES device on the market is mostly not a robust and multifunction device. The need of flexible FES where the parameter that can be adjusted is very important to develop In this paper, a biphasic functional electrical stimulator (FES) has been designed and implemented.. The parameter that need to be controlled in a rehabilitation activity for children with cerebral palsy such as voltage, current, frequency and pulse width. The main parts in the design of the simple biphasic functional electrical stimulator are controller, a digital-to-analog converter, and a constant current source. The constant current source consists of a biphasic amplifier, summing amplifier and Howland pump charge circuit. The result show that the Functional Electrical Stimulator developed capable to meet with the performance of the stimulated design in Proteus and capable to achieved the desired output needed for rehabilitation for children with cerebral palsy.\",\"PeriodicalId\":285507,\"journal\":{\"name\":\"2021 11th IEEE International Conference on Control System, Computing and Engineering (ICCSCE)\",\"volume\":\"60 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 11th IEEE International Conference on Control System, Computing and Engineering (ICCSCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCSCE52189.2021.9530858\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 11th IEEE International Conference on Control System, Computing and Engineering (ICCSCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCSCE52189.2021.9530858","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

功能性电刺激器(FES)已广泛用于康复治疗,然而,在脑瘫儿童中,对合适的FES装置的需求至关重要。目前市场上可用的FES设备大多不是一个强大的多功能设备。本文设计并实现了一种双相功能电刺激器(FES)。脑瘫儿童康复活动中需要控制的参数,如电压、电流、频率和脉宽。简单的双相功能电刺激器的设计主要由控制器、数模转换器和恒流源组成。恒流源由双相放大器、加和放大器和霍兰德泵充电电路组成。结果表明,所开发的功能性电刺激器能够满足Proteus中刺激设计的性能,能够达到脑瘫儿童康复所需的输出。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Flexible Biphasic Functional Electrical Stimulator for Children with Cerebral Palsy
The functional electrical stimulator, FES has been extensively used for rehabilitation, however, in children with cerebral palsy, the need for a suitable FES device is vital. The current available FES device on the market is mostly not a robust and multifunction device. The need of flexible FES where the parameter that can be adjusted is very important to develop In this paper, a biphasic functional electrical stimulator (FES) has been designed and implemented.. The parameter that need to be controlled in a rehabilitation activity for children with cerebral palsy such as voltage, current, frequency and pulse width. The main parts in the design of the simple biphasic functional electrical stimulator are controller, a digital-to-analog converter, and a constant current source. The constant current source consists of a biphasic amplifier, summing amplifier and Howland pump charge circuit. The result show that the Functional Electrical Stimulator developed capable to meet with the performance of the stimulated design in Proteus and capable to achieved the desired output needed for rehabilitation for children with cerebral palsy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信