高压直流系统中数据中心用数字峰值电流型DC-DC变换器

K. Kajiwara, F. Kurokawa, H. Maruta, Y. Shibata, K. Hirose
{"title":"高压直流系统中数据中心用数字峰值电流型DC-DC变换器","authors":"K. Kajiwara, F. Kurokawa, H. Maruta, Y. Shibata, K. Hirose","doi":"10.1109/INTLEC.2015.7572362","DOIUrl":null,"url":null,"abstract":"The purpose of this paper is to present the digital peak current mode phase-shifted full-bridge zero volt switching dc-dc converter for the data center in the higher voltage direct current (HVDC) system, and show its transient response. The proposed peak current mode control circuit is composed of the RC integrator and comparator only and can detect the peak current in real time. At first, the basic operation of proposed method is confirmed by using the buck type dc-dc converter. Furthermore, the proposed method is applied to the prototype of 380V phase-shifted full-bridge zero volt switching dc-dc converter. The system has to be always stable in the transient response even if the input voltage is changed. As a result, the convergence time of output voltage is improved by about 50% compared with the conventional digital voltage mode control when the input voltage is 380V and 300V.","PeriodicalId":211948,"journal":{"name":"2015 IEEE International Telecommunications Energy Conference (INTELEC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Digital peak current mode DC-DC converter for data center in HVDC system\",\"authors\":\"K. Kajiwara, F. Kurokawa, H. Maruta, Y. Shibata, K. Hirose\",\"doi\":\"10.1109/INTLEC.2015.7572362\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of this paper is to present the digital peak current mode phase-shifted full-bridge zero volt switching dc-dc converter for the data center in the higher voltage direct current (HVDC) system, and show its transient response. The proposed peak current mode control circuit is composed of the RC integrator and comparator only and can detect the peak current in real time. At first, the basic operation of proposed method is confirmed by using the buck type dc-dc converter. Furthermore, the proposed method is applied to the prototype of 380V phase-shifted full-bridge zero volt switching dc-dc converter. The system has to be always stable in the transient response even if the input voltage is changed. As a result, the convergence time of output voltage is improved by about 50% compared with the conventional digital voltage mode control when the input voltage is 380V and 300V.\",\"PeriodicalId\":211948,\"journal\":{\"name\":\"2015 IEEE International Telecommunications Energy Conference (INTELEC)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE International Telecommunications Energy Conference (INTELEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INTLEC.2015.7572362\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Telecommunications Energy Conference (INTELEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTLEC.2015.7572362","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

本文提出了一种适用于数据中心高压直流(HVDC)系统的数字峰值电流模式移相全桥零伏开关dc-dc变换器,并给出了其瞬态响应。所提出的峰值电流模式控制电路仅由RC积分器和比较器组成,能够实时检测峰值电流。首先,利用降压型dc-dc变换器验证了所提方法的基本工作原理。并将该方法应用于380V移相全桥零伏开关dc-dc变换器样机中。即使输入电压发生变化,系统也必须在瞬态响应中保持稳定。结果表明,当输入电压为380V和300V时,输出电压的收敛时间比传统数字电压模式控制提高了50%左右。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Digital peak current mode DC-DC converter for data center in HVDC system
The purpose of this paper is to present the digital peak current mode phase-shifted full-bridge zero volt switching dc-dc converter for the data center in the higher voltage direct current (HVDC) system, and show its transient response. The proposed peak current mode control circuit is composed of the RC integrator and comparator only and can detect the peak current in real time. At first, the basic operation of proposed method is confirmed by using the buck type dc-dc converter. Furthermore, the proposed method is applied to the prototype of 380V phase-shifted full-bridge zero volt switching dc-dc converter. The system has to be always stable in the transient response even if the input voltage is changed. As a result, the convergence time of output voltage is improved by about 50% compared with the conventional digital voltage mode control when the input voltage is 380V and 300V.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信