用于改进真空辅助封闭的对吸管出口的T尾结构。

S. Ram, Siddha K Loka Vijayan, A. Kini
{"title":"用于改进真空辅助封闭的对吸管出口的T尾结构。","authors":"S. Ram, Siddha K Loka Vijayan, A. Kini","doi":"10.5580/2cb6","DOIUrl":null,"url":null,"abstract":"Many modified vacuum assisted closure methods have been proposed as an alternative to original VAC which are simple and cost-effective. M Singh et al has proposed the idea of a poor man’s VAC (1-2). We would like to suggest few modifications in the methodology considering which will improve the efficiency of poor man’s VAC. The port of exit of the suction tubing from the dressing remains a potential site of leakage. For the use of non electrical suction devices it is necessary to have complete leak proof dressing. Every attempt has to be made to minimize the leak. We recommend Ttailing of suction tubing which prevents leakage significantly from our experience. INTRODUCTION Many modified vacuum assisted closure methods have been proposed as an alternative to original VAC which are simple and cost-effective. M Singh et al has proposed the idea of a poor man’s VAC (1-2). We would like to suggest few modifications in the methodology considering which will improve the efficiency of poor man’s VAC. The port of exit of the suction tubing from the dressing remains a potential site of leakage. For the use of non electrical suction devices it is necessary to have complete leak proof dressing. Every attempt has to be made to minimize the leak. We recommend Ttailing of suction tubing which prevents leakage significantly from our experience. METHODOLOGY The opsite is applied in such a manner that the tubing is lifted one to two inches beyond the edge of the wound by the assistant, and the opsite is adhered to the whole circumference of the tubing and opposing beneath the suction tubing by the applicant in a key hole fashion creating an air tight seal towards the periphery. The “wings” of the opsite is adhered to the skin surface. Now the cross section appears a T shape (Figure 1 ). When this procedure is not performed there is always a chance of peritubal leak from the triangular dead space area tracking along the tubing into the wound especially when the opsite is streched. This procedure prevents the leakage and the efficiency of modified VAC remains same for varying size of tubing. This process is similar to creation of witzel tube for feeding jejunostomy. Figure 1 Figure 1. (T tail configuration in different views ) ADVANTAGES Avoids tunneling through the tissue as much as possible preventing the tissue damage and risk of spread of infection. Change of tubing easily, frequently with every change of dressing Avoiding pain and discomfort to the patient T Tail Configuration Of Opsite On Suction Tubing Outlet For Modified Vacuum Assisted Closure. 2 of 3 Avoids unnecessary usage of adhesive plasters in attempt to sealing the leak. It is easy, comfortable, cost-effective and decreases frequent monitoring for leakage. Patients are relatively ambulant when the negative suction can be maintained through using 50 cc syringes and romovac Though the leakage chances are more in regions involving ankle, groin, axilla, and uneven surfaces , pedal suction device with calibrated vacuum gauge can maintain for a longer period than usual. Figure 2 Figure 2: Measurement of negative pressure with suction gauge with syringe type, romovac and mucus sucker. The 50 cc syringe piston is held in position with a 20 cc syringe piston. A standard 50cc syringe is able to create a maximum amount of 450 mm hg pressure. A standard romovac drain is able to create a negative pressure of 75 mm hg pressure and a mucus sucker produces a vacuum of similar amount. We have used infant feeding tube, ryle’s tube and suction catheters as suction tubing’s with good efficacy and these materials are readily available in government hospitals. Figure 3 Figure 3: Wound healing after application of modified VAC with pedal suction. It is beyond doubt the results are gratifying with poor man’s VAC, we totally agree with the results. With the Ttailing the performance can be more enhanced in low resource setting. Wounds of extensive surface area is are the limiting factor for poor man’s VAC as there are multiple sites of leakage, hence may require a motorized suction device or central vacuum for maintaining the vacuum depending on the resource setting. Vacuum dressing has to be done with great caution or avoided in peripheral vascular disease (3). Further studies regarding the microbial clearance rate, wound contraction time, bed occupancy, patient’s compliance are required to formulate guidelines and standardize poor man’s VAC. Simpler Low cost vacuum devices like these need to be encouraged, educated and improved with modifications which are user as well as patient friendly. References 1. M. Singh, R. Singh, S. Singh, V. Pandey, D. Singh: Vacuum assisted Closure in wound management – Poor man’s VAC©. The Internet Journal of Plastic Surgery. 2009;6(1). 2. Danu M , Rosadi S. The Simplest Modified Vacuum Assisted Closure to Treat Chronic Wound : Serial Case Report. Jurnal Plastik Rekonstruksi . 2012 :117-22. 3. Ahmad M ,Malik SA .Vacuum Assisted Closure Therapy: Role in Modern Plastic Surgery. JLUMHS 2010; 9 (2):76-83. T Tail Configuration Of Opsite On Suction Tubing Outlet For Modified Vacuum Assisted Closure. 3 of 3 Author Information Shankar Ram, HS MBBS Junior Resident, Department of General Surgery, Kasturba Medical College, Manipal University Siddha K Loka Vijayan, MBBS Junior Resident, Department of General Surgery, Kasturba Medical College, Manipal University Anand Kini, MCh (Plastic) Associate Professor, Department of General Surgery, Kasturba Medical College, Manipal University","PeriodicalId":284795,"journal":{"name":"The Internet Journal of Plastic Surgery","volume":"69 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"T Tail Configuration Of Opsite On Suction Tubing Outlet For Modified Vacuum Assisted Closure.\",\"authors\":\"S. Ram, Siddha K Loka Vijayan, A. Kini\",\"doi\":\"10.5580/2cb6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Many modified vacuum assisted closure methods have been proposed as an alternative to original VAC which are simple and cost-effective. M Singh et al has proposed the idea of a poor man’s VAC (1-2). We would like to suggest few modifications in the methodology considering which will improve the efficiency of poor man’s VAC. The port of exit of the suction tubing from the dressing remains a potential site of leakage. For the use of non electrical suction devices it is necessary to have complete leak proof dressing. Every attempt has to be made to minimize the leak. We recommend Ttailing of suction tubing which prevents leakage significantly from our experience. INTRODUCTION Many modified vacuum assisted closure methods have been proposed as an alternative to original VAC which are simple and cost-effective. M Singh et al has proposed the idea of a poor man’s VAC (1-2). We would like to suggest few modifications in the methodology considering which will improve the efficiency of poor man’s VAC. The port of exit of the suction tubing from the dressing remains a potential site of leakage. For the use of non electrical suction devices it is necessary to have complete leak proof dressing. Every attempt has to be made to minimize the leak. We recommend Ttailing of suction tubing which prevents leakage significantly from our experience. METHODOLOGY The opsite is applied in such a manner that the tubing is lifted one to two inches beyond the edge of the wound by the assistant, and the opsite is adhered to the whole circumference of the tubing and opposing beneath the suction tubing by the applicant in a key hole fashion creating an air tight seal towards the periphery. The “wings” of the opsite is adhered to the skin surface. Now the cross section appears a T shape (Figure 1 ). When this procedure is not performed there is always a chance of peritubal leak from the triangular dead space area tracking along the tubing into the wound especially when the opsite is streched. This procedure prevents the leakage and the efficiency of modified VAC remains same for varying size of tubing. This process is similar to creation of witzel tube for feeding jejunostomy. Figure 1 Figure 1. (T tail configuration in different views ) ADVANTAGES Avoids tunneling through the tissue as much as possible preventing the tissue damage and risk of spread of infection. Change of tubing easily, frequently with every change of dressing Avoiding pain and discomfort to the patient T Tail Configuration Of Opsite On Suction Tubing Outlet For Modified Vacuum Assisted Closure. 2 of 3 Avoids unnecessary usage of adhesive plasters in attempt to sealing the leak. It is easy, comfortable, cost-effective and decreases frequent monitoring for leakage. Patients are relatively ambulant when the negative suction can be maintained through using 50 cc syringes and romovac Though the leakage chances are more in regions involving ankle, groin, axilla, and uneven surfaces , pedal suction device with calibrated vacuum gauge can maintain for a longer period than usual. Figure 2 Figure 2: Measurement of negative pressure with suction gauge with syringe type, romovac and mucus sucker. The 50 cc syringe piston is held in position with a 20 cc syringe piston. A standard 50cc syringe is able to create a maximum amount of 450 mm hg pressure. A standard romovac drain is able to create a negative pressure of 75 mm hg pressure and a mucus sucker produces a vacuum of similar amount. We have used infant feeding tube, ryle’s tube and suction catheters as suction tubing’s with good efficacy and these materials are readily available in government hospitals. Figure 3 Figure 3: Wound healing after application of modified VAC with pedal suction. It is beyond doubt the results are gratifying with poor man’s VAC, we totally agree with the results. With the Ttailing the performance can be more enhanced in low resource setting. Wounds of extensive surface area is are the limiting factor for poor man’s VAC as there are multiple sites of leakage, hence may require a motorized suction device or central vacuum for maintaining the vacuum depending on the resource setting. Vacuum dressing has to be done with great caution or avoided in peripheral vascular disease (3). Further studies regarding the microbial clearance rate, wound contraction time, bed occupancy, patient’s compliance are required to formulate guidelines and standardize poor man’s VAC. Simpler Low cost vacuum devices like these need to be encouraged, educated and improved with modifications which are user as well as patient friendly. References 1. M. Singh, R. Singh, S. Singh, V. Pandey, D. Singh: Vacuum assisted Closure in wound management – Poor man’s VAC©. The Internet Journal of Plastic Surgery. 2009;6(1). 2. Danu M , Rosadi S. The Simplest Modified Vacuum Assisted Closure to Treat Chronic Wound : Serial Case Report. Jurnal Plastik Rekonstruksi . 2012 :117-22. 3. Ahmad M ,Malik SA .Vacuum Assisted Closure Therapy: Role in Modern Plastic Surgery. JLUMHS 2010; 9 (2):76-83. T Tail Configuration Of Opsite On Suction Tubing Outlet For Modified Vacuum Assisted Closure. 3 of 3 Author Information Shankar Ram, HS MBBS Junior Resident, Department of General Surgery, Kasturba Medical College, Manipal University Siddha K Loka Vijayan, MBBS Junior Resident, Department of General Surgery, Kasturba Medical College, Manipal University Anand Kini, MCh (Plastic) Associate Professor, Department of General Surgery, Kasturba Medical College, Manipal University\",\"PeriodicalId\":284795,\"journal\":{\"name\":\"The Internet Journal of Plastic Surgery\",\"volume\":\"69 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-01-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Internet Journal of Plastic Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5580/2cb6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Internet Journal of Plastic Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5580/2cb6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

真空辅助闭合治疗:在现代整形外科中的作用。JLUMHS 2010;9(2): 76 - 83。Shankar Ram,马尼帕尔大学Kasturba医学院普通外科专科住院医师Siddha K Loka Vijayan,马尼帕尔大学Kasturba医学院普通外科专科住院医师Anand Kini, MCh(整形)副教授,马尼帕尔大学Kasturba医学院普通外科学系
本文章由计算机程序翻译,如有差异,请以英文原文为准。
T Tail Configuration Of Opsite On Suction Tubing Outlet For Modified Vacuum Assisted Closure.
Many modified vacuum assisted closure methods have been proposed as an alternative to original VAC which are simple and cost-effective. M Singh et al has proposed the idea of a poor man’s VAC (1-2). We would like to suggest few modifications in the methodology considering which will improve the efficiency of poor man’s VAC. The port of exit of the suction tubing from the dressing remains a potential site of leakage. For the use of non electrical suction devices it is necessary to have complete leak proof dressing. Every attempt has to be made to minimize the leak. We recommend Ttailing of suction tubing which prevents leakage significantly from our experience. INTRODUCTION Many modified vacuum assisted closure methods have been proposed as an alternative to original VAC which are simple and cost-effective. M Singh et al has proposed the idea of a poor man’s VAC (1-2). We would like to suggest few modifications in the methodology considering which will improve the efficiency of poor man’s VAC. The port of exit of the suction tubing from the dressing remains a potential site of leakage. For the use of non electrical suction devices it is necessary to have complete leak proof dressing. Every attempt has to be made to minimize the leak. We recommend Ttailing of suction tubing which prevents leakage significantly from our experience. METHODOLOGY The opsite is applied in such a manner that the tubing is lifted one to two inches beyond the edge of the wound by the assistant, and the opsite is adhered to the whole circumference of the tubing and opposing beneath the suction tubing by the applicant in a key hole fashion creating an air tight seal towards the periphery. The “wings” of the opsite is adhered to the skin surface. Now the cross section appears a T shape (Figure 1 ). When this procedure is not performed there is always a chance of peritubal leak from the triangular dead space area tracking along the tubing into the wound especially when the opsite is streched. This procedure prevents the leakage and the efficiency of modified VAC remains same for varying size of tubing. This process is similar to creation of witzel tube for feeding jejunostomy. Figure 1 Figure 1. (T tail configuration in different views ) ADVANTAGES Avoids tunneling through the tissue as much as possible preventing the tissue damage and risk of spread of infection. Change of tubing easily, frequently with every change of dressing Avoiding pain and discomfort to the patient T Tail Configuration Of Opsite On Suction Tubing Outlet For Modified Vacuum Assisted Closure. 2 of 3 Avoids unnecessary usage of adhesive plasters in attempt to sealing the leak. It is easy, comfortable, cost-effective and decreases frequent monitoring for leakage. Patients are relatively ambulant when the negative suction can be maintained through using 50 cc syringes and romovac Though the leakage chances are more in regions involving ankle, groin, axilla, and uneven surfaces , pedal suction device with calibrated vacuum gauge can maintain for a longer period than usual. Figure 2 Figure 2: Measurement of negative pressure with suction gauge with syringe type, romovac and mucus sucker. The 50 cc syringe piston is held in position with a 20 cc syringe piston. A standard 50cc syringe is able to create a maximum amount of 450 mm hg pressure. A standard romovac drain is able to create a negative pressure of 75 mm hg pressure and a mucus sucker produces a vacuum of similar amount. We have used infant feeding tube, ryle’s tube and suction catheters as suction tubing’s with good efficacy and these materials are readily available in government hospitals. Figure 3 Figure 3: Wound healing after application of modified VAC with pedal suction. It is beyond doubt the results are gratifying with poor man’s VAC, we totally agree with the results. With the Ttailing the performance can be more enhanced in low resource setting. Wounds of extensive surface area is are the limiting factor for poor man’s VAC as there are multiple sites of leakage, hence may require a motorized suction device or central vacuum for maintaining the vacuum depending on the resource setting. Vacuum dressing has to be done with great caution or avoided in peripheral vascular disease (3). Further studies regarding the microbial clearance rate, wound contraction time, bed occupancy, patient’s compliance are required to formulate guidelines and standardize poor man’s VAC. Simpler Low cost vacuum devices like these need to be encouraged, educated and improved with modifications which are user as well as patient friendly. References 1. M. Singh, R. Singh, S. Singh, V. Pandey, D. Singh: Vacuum assisted Closure in wound management – Poor man’s VAC©. The Internet Journal of Plastic Surgery. 2009;6(1). 2. Danu M , Rosadi S. The Simplest Modified Vacuum Assisted Closure to Treat Chronic Wound : Serial Case Report. Jurnal Plastik Rekonstruksi . 2012 :117-22. 3. Ahmad M ,Malik SA .Vacuum Assisted Closure Therapy: Role in Modern Plastic Surgery. JLUMHS 2010; 9 (2):76-83. T Tail Configuration Of Opsite On Suction Tubing Outlet For Modified Vacuum Assisted Closure. 3 of 3 Author Information Shankar Ram, HS MBBS Junior Resident, Department of General Surgery, Kasturba Medical College, Manipal University Siddha K Loka Vijayan, MBBS Junior Resident, Department of General Surgery, Kasturba Medical College, Manipal University Anand Kini, MCh (Plastic) Associate Professor, Department of General Surgery, Kasturba Medical College, Manipal University
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信