{"title":"旋转等离子体消毒配件","authors":"K. Ivanov, I. Iliev, S. Tabakov","doi":"10.1109/ET50336.2020.9238201","DOIUrl":null,"url":null,"abstract":"As is known the plasma treatment inactivates microbial pathogens, mainly bacteria, fungi, and viruses and is widely used for sterilization of medical and dental devices, as well as agricultural products. This article reviews the existing problems connected with the disinfection/sterilization of heat-sensitive biomaterials and structures as: skin, wounds, meat animal products, etc. The design of a new type low-temperature plasma disinfection/sterilization accessory featuring small size and easy usability is presented. The achieved results at initial tests are evaluated in the context of applicability for sterilization procedures in medical practice.","PeriodicalId":178356,"journal":{"name":"2020 XXIX International Scientific Conference Electronics (ET)","volume":"221 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rotary Plasma Disinfection Accessory\",\"authors\":\"K. Ivanov, I. Iliev, S. Tabakov\",\"doi\":\"10.1109/ET50336.2020.9238201\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As is known the plasma treatment inactivates microbial pathogens, mainly bacteria, fungi, and viruses and is widely used for sterilization of medical and dental devices, as well as agricultural products. This article reviews the existing problems connected with the disinfection/sterilization of heat-sensitive biomaterials and structures as: skin, wounds, meat animal products, etc. The design of a new type low-temperature plasma disinfection/sterilization accessory featuring small size and easy usability is presented. The achieved results at initial tests are evaluated in the context of applicability for sterilization procedures in medical practice.\",\"PeriodicalId\":178356,\"journal\":{\"name\":\"2020 XXIX International Scientific Conference Electronics (ET)\",\"volume\":\"221 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 XXIX International Scientific Conference Electronics (ET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ET50336.2020.9238201\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 XXIX International Scientific Conference Electronics (ET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ET50336.2020.9238201","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
As is known the plasma treatment inactivates microbial pathogens, mainly bacteria, fungi, and viruses and is widely used for sterilization of medical and dental devices, as well as agricultural products. This article reviews the existing problems connected with the disinfection/sterilization of heat-sensitive biomaterials and structures as: skin, wounds, meat animal products, etc. The design of a new type low-temperature plasma disinfection/sterilization accessory featuring small size and easy usability is presented. The achieved results at initial tests are evaluated in the context of applicability for sterilization procedures in medical practice.