吸入器装置:过去、现在和未来

Sarah Utley
{"title":"吸入器装置:过去、现在和未来","authors":"Sarah Utley","doi":"10.33590/emjrespir/10314624","DOIUrl":null,"url":null,"abstract":"Inhaler handling errors negatively impact asthma control and represent one of the most common challenges in asthma management. Overcoming inhaler handling errors can be achieved by increased awareness of errors, more explicit and consistent training in inhaler use, and development of ‘intuitive’ devices. Clinical studies have shown that dry powder inhalers (DPIs) have better dose consistency and delivery to the lungs, but this is also dependent on device and inhalation technique. In addition, recent clinical studies have demonstrated that Spiromax® is a more intuitive device than Turbuhaler®. In studies analysing patient device mastery, intuitive devices are preferred by patients because they are easy/simple to use and have effective dose delivery.","PeriodicalId":300382,"journal":{"name":"EMJ Respiratory","volume":"126 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Inhaler Devices: The past, the Present, and the Future\",\"authors\":\"Sarah Utley\",\"doi\":\"10.33590/emjrespir/10314624\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Inhaler handling errors negatively impact asthma control and represent one of the most common challenges in asthma management. Overcoming inhaler handling errors can be achieved by increased awareness of errors, more explicit and consistent training in inhaler use, and development of ‘intuitive’ devices. Clinical studies have shown that dry powder inhalers (DPIs) have better dose consistency and delivery to the lungs, but this is also dependent on device and inhalation technique. In addition, recent clinical studies have demonstrated that Spiromax® is a more intuitive device than Turbuhaler®. In studies analysing patient device mastery, intuitive devices are preferred by patients because they are easy/simple to use and have effective dose delivery.\",\"PeriodicalId\":300382,\"journal\":{\"name\":\"EMJ Respiratory\",\"volume\":\"126 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"EMJ Respiratory\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33590/emjrespir/10314624\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"EMJ Respiratory","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33590/emjrespir/10314624","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

吸入器处理错误对哮喘控制产生负面影响,是哮喘管理中最常见的挑战之一。克服吸入器操作错误可以通过提高错误意识、更明确和一致的吸入器使用培训以及开发“直观”装置来实现。临床研究表明,干粉吸入器(dpi)具有更好的剂量一致性和肺输送,但这也取决于设备和吸入技术。此外,最近的临床研究表明,Spiromax®是比Turbuhaler®更直观的设备。在分析患者对器械的掌握程度的研究中,直观的器械因为使用方便、给药有效而受到患者的青睐。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Inhaler Devices: The past, the Present, and the Future
Inhaler handling errors negatively impact asthma control and represent one of the most common challenges in asthma management. Overcoming inhaler handling errors can be achieved by increased awareness of errors, more explicit and consistent training in inhaler use, and development of ‘intuitive’ devices. Clinical studies have shown that dry powder inhalers (DPIs) have better dose consistency and delivery to the lungs, but this is also dependent on device and inhalation technique. In addition, recent clinical studies have demonstrated that Spiromax® is a more intuitive device than Turbuhaler®. In studies analysing patient device mastery, intuitive devices are preferred by patients because they are easy/simple to use and have effective dose delivery.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信