红外激光传感器新技术

T. Hanafy
{"title":"红外激光传感器新技术","authors":"T. Hanafy","doi":"10.1109/SIECPC.2011.5876977","DOIUrl":null,"url":null,"abstract":"The effect of IR laser pulses fluencies on the dielectric properties, X-ray diffraction, and Fourier Transform Infrared spectroscopy (FTIR), for Makrofol-DE 1–1 CC polycarbonate has been investigated in the temperature and frequency ranges of 300–375K and 10kHz–4MHz, respectively. IR laser fluencies are set from 0.47 to 7.07 J/cm2. Three relaxation processes namely, a, p, and y have been obtained. X-ray diffraction and FTIR spectroscopy have revealed that, the irradiation of Makrofol at the fluence range 0.94–7.07 J/cm2 causes crosslinking formation inside the sample. The attained results suggested strongly the applicability of Makrofol-DE in IR laser pulses sensors.","PeriodicalId":125634,"journal":{"name":"2011 Saudi International Electronics, Communications and Photonics Conference (SIECPC)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"New techniques for IR laser sensors\",\"authors\":\"T. Hanafy\",\"doi\":\"10.1109/SIECPC.2011.5876977\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The effect of IR laser pulses fluencies on the dielectric properties, X-ray diffraction, and Fourier Transform Infrared spectroscopy (FTIR), for Makrofol-DE 1–1 CC polycarbonate has been investigated in the temperature and frequency ranges of 300–375K and 10kHz–4MHz, respectively. IR laser fluencies are set from 0.47 to 7.07 J/cm2. Three relaxation processes namely, a, p, and y have been obtained. X-ray diffraction and FTIR spectroscopy have revealed that, the irradiation of Makrofol at the fluence range 0.94–7.07 J/cm2 causes crosslinking formation inside the sample. The attained results suggested strongly the applicability of Makrofol-DE in IR laser pulses sensors.\",\"PeriodicalId\":125634,\"journal\":{\"name\":\"2011 Saudi International Electronics, Communications and Photonics Conference (SIECPC)\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-04-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 Saudi International Electronics, Communications and Photonics Conference (SIECPC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIECPC.2011.5876977\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Saudi International Electronics, Communications and Photonics Conference (SIECPC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIECPC.2011.5876977","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在300-375K和10kHz-4MHz的温度和频率范围内,研究了红外激光脉冲对makrofolo - de 1-1 CC聚碳酸酯的介电性能、x射线衍射和傅里叶变换红外光谱(FTIR)的影响。红外激光光通量设置在0.47到7.07 J/cm2之间。得到了a、p、y三个弛豫过程。x射线衍射和红外光谱分析表明,在0.94 ~ 7.07 J/cm2辐照下,样品内部形成交联。所得结果有力地说明了makrofolo - de在红外激光脉冲传感器中的适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
New techniques for IR laser sensors
The effect of IR laser pulses fluencies on the dielectric properties, X-ray diffraction, and Fourier Transform Infrared spectroscopy (FTIR), for Makrofol-DE 1–1 CC polycarbonate has been investigated in the temperature and frequency ranges of 300–375K and 10kHz–4MHz, respectively. IR laser fluencies are set from 0.47 to 7.07 J/cm2. Three relaxation processes namely, a, p, and y have been obtained. X-ray diffraction and FTIR spectroscopy have revealed that, the irradiation of Makrofol at the fluence range 0.94–7.07 J/cm2 causes crosslinking formation inside the sample. The attained results suggested strongly the applicability of Makrofol-DE in IR laser pulses sensors.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信