分布式发电中带外电流环的三相逆变器无缝传输策略

Zeng Liu, Jinjun Liu
{"title":"分布式发电中带外电流环的三相逆变器无缝传输策略","authors":"Zeng Liu, Jinjun Liu","doi":"10.1109/ECCE.2010.5617704","DOIUrl":null,"url":null,"abstract":"This paper presents a control strategy for three phase inverter to transfer between grid-tied and islanding mode in distributed generation. It is with an inner load voltage loop and an outer grid current loop. During the transition, the regulators are not changed, as the limiters are of effect. As a result, the load voltage is very smooth during the transfer, and the realization is very simple.","PeriodicalId":161915,"journal":{"name":"2010 IEEE Energy Conversion Congress and Exposition","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Seamless transfer strategy with outer current loop for three phase inverter in distributed generation\",\"authors\":\"Zeng Liu, Jinjun Liu\",\"doi\":\"10.1109/ECCE.2010.5617704\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a control strategy for three phase inverter to transfer between grid-tied and islanding mode in distributed generation. It is with an inner load voltage loop and an outer grid current loop. During the transition, the regulators are not changed, as the limiters are of effect. As a result, the load voltage is very smooth during the transfer, and the realization is very simple.\",\"PeriodicalId\":161915,\"journal\":{\"name\":\"2010 IEEE Energy Conversion Congress and Exposition\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE Energy Conversion Congress and Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECCE.2010.5617704\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE Energy Conversion Congress and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE.2010.5617704","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

本文提出了一种分布式发电中三相逆变器并网与孤岛转换的控制策略。它具有内负载电压环和外电网电流环。在过渡期间,监管机构没有改变,因为限制措施仍然有效。因此,负载电压在传递过程中非常平稳,实现也非常简单。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Seamless transfer strategy with outer current loop for three phase inverter in distributed generation
This paper presents a control strategy for three phase inverter to transfer between grid-tied and islanding mode in distributed generation. It is with an inner load voltage loop and an outer grid current loop. During the transition, the regulators are not changed, as the limiters are of effect. As a result, the load voltage is very smooth during the transfer, and the realization is very simple.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信