Nutthanan Wanluk, C. Pintavirooj, T. Treebupachatsakul
{"title":"x射线校准幻影的图像处理","authors":"Nutthanan Wanluk, C. Pintavirooj, T. Treebupachatsakul","doi":"10.1109/BMEICON.2018.8609973","DOIUrl":null,"url":null,"abstract":"Medical device calibration is the process of ensuring that there is accuracy before using. X-ray imaging device is one of the high-risk medical devices that must be calibrated. The calibration process required these values to be measured; center ray, focal object distance (FOD), resolution, and linearity of the imaging system. But the devices used to measure each of these are expensive. In this paper, a design of the x-ray calibration phantom that is affordable and yet effective is presented. An aluminum rectangular phantom consists of a center ray calibration unit, focal object distance (FOD) calibration unit and Linearity calibration unit. The x-ray image of all the phantom unit can be analyzed automatically by using the digital image processing.","PeriodicalId":232271,"journal":{"name":"2018 11th Biomedical Engineering International Conference (BMEiCON)","volume":"221 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Image Processing for X-ray Calibration Phantom\",\"authors\":\"Nutthanan Wanluk, C. Pintavirooj, T. Treebupachatsakul\",\"doi\":\"10.1109/BMEICON.2018.8609973\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Medical device calibration is the process of ensuring that there is accuracy before using. X-ray imaging device is one of the high-risk medical devices that must be calibrated. The calibration process required these values to be measured; center ray, focal object distance (FOD), resolution, and linearity of the imaging system. But the devices used to measure each of these are expensive. In this paper, a design of the x-ray calibration phantom that is affordable and yet effective is presented. An aluminum rectangular phantom consists of a center ray calibration unit, focal object distance (FOD) calibration unit and Linearity calibration unit. The x-ray image of all the phantom unit can be analyzed automatically by using the digital image processing.\",\"PeriodicalId\":232271,\"journal\":{\"name\":\"2018 11th Biomedical Engineering International Conference (BMEiCON)\",\"volume\":\"221 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 11th Biomedical Engineering International Conference (BMEiCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BMEICON.2018.8609973\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 11th Biomedical Engineering International Conference (BMEiCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BMEICON.2018.8609973","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Medical device calibration is the process of ensuring that there is accuracy before using. X-ray imaging device is one of the high-risk medical devices that must be calibrated. The calibration process required these values to be measured; center ray, focal object distance (FOD), resolution, and linearity of the imaging system. But the devices used to measure each of these are expensive. In this paper, a design of the x-ray calibration phantom that is affordable and yet effective is presented. An aluminum rectangular phantom consists of a center ray calibration unit, focal object distance (FOD) calibration unit and Linearity calibration unit. The x-ray image of all the phantom unit can be analyzed automatically by using the digital image processing.