P/N结二极管的隧道电流测量及其对未来器件设计的影响

P. Solomon, D. Frank, J. Jopling, C. D'Emic, O. Dokumaci, P. Ronsheim, W. Haensch
{"title":"P/N结二极管的隧道电流测量及其对未来器件设计的影响","authors":"P. Solomon, D. Frank, J. Jopling, C. D'Emic, O. Dokumaci, P. Ronsheim, W. Haensch","doi":"10.1109/IEDM.2003.1269260","DOIUrl":null,"url":null,"abstract":"Band-to-band tunneling was studied experimentally in ion-implanted PN junction diodes with profiles representative of present and future silicon CMOS transistors. Measurements were done over a wide range of temperatures and implant parameters. Profile parameters were derived from analysis of CV characteristics, and compared to SIMS analysis. When tunneling current was plotted against distance (tunneling distance, corrected for band curvature) a quasi-universal exponential reduction of tunneling current vs. tunneling distance was found with an attenuation length of 0.38 nm, and an extrapolated tunneling current at zero tunnel distance of 5.3/spl times/10/sup 7/ A/cm/sup 2/ at 300 K. These results were used to estimate drain-substrate currents in future scaled CMOS, and it was concluded that it will be challenging to make the ITRS 2002 roadmap projections on leakage current for the low operating power and low standby power options without more innovation and device design changes.","PeriodicalId":344286,"journal":{"name":"IEEE International Electron Devices Meeting 2003","volume":"134 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"Tunnel current measurements on P/N junction diodes and implications for future device design\",\"authors\":\"P. Solomon, D. Frank, J. Jopling, C. D'Emic, O. Dokumaci, P. Ronsheim, W. Haensch\",\"doi\":\"10.1109/IEDM.2003.1269260\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Band-to-band tunneling was studied experimentally in ion-implanted PN junction diodes with profiles representative of present and future silicon CMOS transistors. Measurements were done over a wide range of temperatures and implant parameters. Profile parameters were derived from analysis of CV characteristics, and compared to SIMS analysis. When tunneling current was plotted against distance (tunneling distance, corrected for band curvature) a quasi-universal exponential reduction of tunneling current vs. tunneling distance was found with an attenuation length of 0.38 nm, and an extrapolated tunneling current at zero tunnel distance of 5.3/spl times/10/sup 7/ A/cm/sup 2/ at 300 K. These results were used to estimate drain-substrate currents in future scaled CMOS, and it was concluded that it will be challenging to make the ITRS 2002 roadmap projections on leakage current for the low operating power and low standby power options without more innovation and device design changes.\",\"PeriodicalId\":344286,\"journal\":{\"name\":\"IEEE International Electron Devices Meeting 2003\",\"volume\":\"134 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-12-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE International Electron Devices Meeting 2003\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEDM.2003.1269260\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE International Electron Devices Meeting 2003","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEDM.2003.1269260","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

摘要

对离子注入PN结二极管的带间隧道效应进行了实验研究,该二极管具有代表当前和未来硅CMOS晶体管的轮廓。测量是在很宽的温度和植入物参数范围内完成的。从CV特征分析中得出剖面参数,并与SIMS分析进行比较。当隧道电流与隧道距离(隧道距离,修正了带曲率)的关系时,发现隧道电流随隧道距离的准普遍指数减少,衰减长度为0.38 nm,并且在300 K时,零隧道距离时的外推隧道电流为5.3/spl乘以/10/sup 7/ a /cm/sup 2/。这些结果被用于估计未来规模CMOS的漏极-衬底电流,并得出结论,如果没有更多的创新和器件设计变化,要对低工作功率和低待机功率选项进行ITRS 2002路线图预测将是具有挑战性的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Tunnel current measurements on P/N junction diodes and implications for future device design
Band-to-band tunneling was studied experimentally in ion-implanted PN junction diodes with profiles representative of present and future silicon CMOS transistors. Measurements were done over a wide range of temperatures and implant parameters. Profile parameters were derived from analysis of CV characteristics, and compared to SIMS analysis. When tunneling current was plotted against distance (tunneling distance, corrected for band curvature) a quasi-universal exponential reduction of tunneling current vs. tunneling distance was found with an attenuation length of 0.38 nm, and an extrapolated tunneling current at zero tunnel distance of 5.3/spl times/10/sup 7/ A/cm/sup 2/ at 300 K. These results were used to estimate drain-substrate currents in future scaled CMOS, and it was concluded that it will be challenging to make the ITRS 2002 roadmap projections on leakage current for the low operating power and low standby power options without more innovation and device design changes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信