A. Omelchuk, S. Makarevych, A. Petrenko, Yaroslav Yarosh
{"title":"有源分布式发电线路具有远程启动和依赖定时器延迟的远程保护设置选择的建模准则","authors":"A. Omelchuk, S. Makarevych, A. Petrenko, Yaroslav Yarosh","doi":"10.1109/KhPIWeek53812.2021.9570005","DOIUrl":null,"url":null,"abstract":"The parameters of special remote protections with remote start-up and resistance-dependent short-circuit loop time delay for branched partitioned lines with distributed generation sources are obtained, which take into account the peculiarities of parameters, operating modes and conditions of their operation. The necessary protection characteristics that can be used in the development of remote protection of such lines with a voltage of 6…20 kV are determined. The expediency using the circuit of connection of remote protection to linear voltages and phase current differences. The separate protection against double earth fault is used. In the absence of the latter - the scheme of connection to linear voltages and phase currents. The remote impedance protection is proposed to be evaluated by the value of the maximum arc. It is determined at a given coefficient of sensitivity of the voltage drop in the place of protection in the event of a short circuit.","PeriodicalId":365896,"journal":{"name":"2021 IEEE 2nd KhPI Week on Advanced Technology (KhPIWeek)","volume":"888 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Modeling criteria for selection of remote protection settings with remote starting and dependent timer delay on lines with sources distributed generation\",\"authors\":\"A. Omelchuk, S. Makarevych, A. Petrenko, Yaroslav Yarosh\",\"doi\":\"10.1109/KhPIWeek53812.2021.9570005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The parameters of special remote protections with remote start-up and resistance-dependent short-circuit loop time delay for branched partitioned lines with distributed generation sources are obtained, which take into account the peculiarities of parameters, operating modes and conditions of their operation. The necessary protection characteristics that can be used in the development of remote protection of such lines with a voltage of 6…20 kV are determined. The expediency using the circuit of connection of remote protection to linear voltages and phase current differences. The separate protection against double earth fault is used. In the absence of the latter - the scheme of connection to linear voltages and phase currents. The remote impedance protection is proposed to be evaluated by the value of the maximum arc. It is determined at a given coefficient of sensitivity of the voltage drop in the place of protection in the event of a short circuit.\",\"PeriodicalId\":365896,\"journal\":{\"name\":\"2021 IEEE 2nd KhPI Week on Advanced Technology (KhPIWeek)\",\"volume\":\"888 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE 2nd KhPI Week on Advanced Technology (KhPIWeek)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/KhPIWeek53812.2021.9570005\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 2nd KhPI Week on Advanced Technology (KhPIWeek)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/KhPIWeek53812.2021.9570005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Modeling criteria for selection of remote protection settings with remote starting and dependent timer delay on lines with sources distributed generation
The parameters of special remote protections with remote start-up and resistance-dependent short-circuit loop time delay for branched partitioned lines with distributed generation sources are obtained, which take into account the peculiarities of parameters, operating modes and conditions of their operation. The necessary protection characteristics that can be used in the development of remote protection of such lines with a voltage of 6…20 kV are determined. The expediency using the circuit of connection of remote protection to linear voltages and phase current differences. The separate protection against double earth fault is used. In the absence of the latter - the scheme of connection to linear voltages and phase currents. The remote impedance protection is proposed to be evaluated by the value of the maximum arc. It is determined at a given coefficient of sensitivity of the voltage drop in the place of protection in the event of a short circuit.