{"title":"有源分布式发电线路具有远程启动和依赖定时器延迟的远程保护设置选择的建模准则","authors":"A. Omelchuk, S. Makarevych, A. Petrenko, Yaroslav Yarosh","doi":"10.1109/KhPIWeek53812.2021.9570005","DOIUrl":null,"url":null,"abstract":"The parameters of special remote protections with remote start-up and resistance-dependent short-circuit loop time delay for branched partitioned lines with distributed generation sources are obtained, which take into account the peculiarities of parameters, operating modes and conditions of their operation. The necessary protection characteristics that can be used in the development of remote protection of such lines with a voltage of 6…20 kV are determined. The expediency using the circuit of connection of remote protection to linear voltages and phase current differences. The separate protection against double earth fault is used. In the absence of the latter - the scheme of connection to linear voltages and phase currents. The remote impedance protection is proposed to be evaluated by the value of the maximum arc. It is determined at a given coefficient of sensitivity of the voltage drop in the place of protection in the event of a short circuit.","PeriodicalId":365896,"journal":{"name":"2021 IEEE 2nd KhPI Week on Advanced Technology (KhPIWeek)","volume":"888 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Modeling criteria for selection of remote protection settings with remote starting and dependent timer delay on lines with sources distributed generation\",\"authors\":\"A. Omelchuk, S. Makarevych, A. Petrenko, Yaroslav Yarosh\",\"doi\":\"10.1109/KhPIWeek53812.2021.9570005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The parameters of special remote protections with remote start-up and resistance-dependent short-circuit loop time delay for branched partitioned lines with distributed generation sources are obtained, which take into account the peculiarities of parameters, operating modes and conditions of their operation. The necessary protection characteristics that can be used in the development of remote protection of such lines with a voltage of 6…20 kV are determined. The expediency using the circuit of connection of remote protection to linear voltages and phase current differences. The separate protection against double earth fault is used. In the absence of the latter - the scheme of connection to linear voltages and phase currents. The remote impedance protection is proposed to be evaluated by the value of the maximum arc. It is determined at a given coefficient of sensitivity of the voltage drop in the place of protection in the event of a short circuit.\",\"PeriodicalId\":365896,\"journal\":{\"name\":\"2021 IEEE 2nd KhPI Week on Advanced Technology (KhPIWeek)\",\"volume\":\"888 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE 2nd KhPI Week on Advanced Technology (KhPIWeek)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/KhPIWeek53812.2021.9570005\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 2nd KhPI Week on Advanced Technology (KhPIWeek)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/KhPIWeek53812.2021.9570005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

考虑到分布式电源分岔线路的参数、运行方式和运行条件的特殊性,得到了具有远程启动和电阻相关短路回路延时的特殊远程保护的参数。确定了可用于开发电压为6…20kv的此类线路的远程保护的必要保护特性。采用远程保护连接电路对线性电压和相电流差的方便性。采用双地隔离保护。在没有后者的情况下-连接到线性电压和相电流的方案。提出了用最大电弧值来评价远端阻抗保护的方法。它是根据短路时保护地电压降的给定灵敏度系数确定的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Modeling criteria for selection of remote protection settings with remote starting and dependent timer delay on lines with sources distributed generation
The parameters of special remote protections with remote start-up and resistance-dependent short-circuit loop time delay for branched partitioned lines with distributed generation sources are obtained, which take into account the peculiarities of parameters, operating modes and conditions of their operation. The necessary protection characteristics that can be used in the development of remote protection of such lines with a voltage of 6…20 kV are determined. The expediency using the circuit of connection of remote protection to linear voltages and phase current differences. The separate protection against double earth fault is used. In the absence of the latter - the scheme of connection to linear voltages and phase currents. The remote impedance protection is proposed to be evaluated by the value of the maximum arc. It is determined at a given coefficient of sensitivity of the voltage drop in the place of protection in the event of a short circuit.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信