Fairus Muhamad Darus, A. Zain-Ahmed, Mohd Talib Latif
{"title":"马来西亚沙阿南的排屋住宅室内和室外空气质量","authors":"Fairus Muhamad Darus, A. Zain-Ahmed, Mohd Talib Latif","doi":"10.1109/ISESEE.2011.5977090","DOIUrl":null,"url":null,"abstract":"The indoor and outdoor air quality at four residential buildings in Shah Alam, Selangor was investigated. The concentrations of carbon monoxide (CO), carbon dioxide (CO<inf>2</inf>), and particulate matters (PM<inf>10</inf>) in outdoor and indoor of the houses were determined for 8 hour period. The mean concentration of CO, CO<inf>2</inf> and PM<inf>10</inf> indoor was in the range 0.24–0.31 ppm, 437.18–549.57 ppm and 94.00–124.00 μg/m<sup>3</sup> respectively. The results indicated that all of the average indoor concentrations of CO, CO<inf>2</inf>, and PM<inf>10</inf> were below the limit of Malaysian guideline standards. The indoor/outdoor concentration ratios of all air pollutants were found to be below one, except for CO<inf>2</inf> which seems to be affected by outdoor sources of origin.","PeriodicalId":105476,"journal":{"name":"2011 3rd International Symposium & Exhibition in Sustainable Energy & Environment (ISESEE)","volume":"126 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Terraced residential housing indoor and outdoor air quality in Shah Alam, Malaysia\",\"authors\":\"Fairus Muhamad Darus, A. Zain-Ahmed, Mohd Talib Latif\",\"doi\":\"10.1109/ISESEE.2011.5977090\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The indoor and outdoor air quality at four residential buildings in Shah Alam, Selangor was investigated. The concentrations of carbon monoxide (CO), carbon dioxide (CO<inf>2</inf>), and particulate matters (PM<inf>10</inf>) in outdoor and indoor of the houses were determined for 8 hour period. The mean concentration of CO, CO<inf>2</inf> and PM<inf>10</inf> indoor was in the range 0.24–0.31 ppm, 437.18–549.57 ppm and 94.00–124.00 μg/m<sup>3</sup> respectively. The results indicated that all of the average indoor concentrations of CO, CO<inf>2</inf>, and PM<inf>10</inf> were below the limit of Malaysian guideline standards. The indoor/outdoor concentration ratios of all air pollutants were found to be below one, except for CO<inf>2</inf> which seems to be affected by outdoor sources of origin.\",\"PeriodicalId\":105476,\"journal\":{\"name\":\"2011 3rd International Symposium & Exhibition in Sustainable Energy & Environment (ISESEE)\",\"volume\":\"126 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 3rd International Symposium & Exhibition in Sustainable Energy & Environment (ISESEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISESEE.2011.5977090\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 3rd International Symposium & Exhibition in Sustainable Energy & Environment (ISESEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISESEE.2011.5977090","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

对雪兰莪州沙阿南四栋住宅的室内和室外空气质量进行了调查。在8小时的时间里,测定了房屋室内外一氧化碳(CO)、二氧化碳(CO2)和颗粒物(PM10)的浓度。室内CO、CO2和PM10的平均浓度分别为0.24 ~ 0.31 ppm、437.18 ~ 549.57 ppm和94.00 ~ 124.00 μg/m3。结果表明,所有室内CO、CO2和PM10的平均浓度均低于马来西亚指导标准的限值。所有空气污染物的室内/室外浓度比均低于1,但二氧化碳似乎受到室外来源的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Terraced residential housing indoor and outdoor air quality in Shah Alam, Malaysia
The indoor and outdoor air quality at four residential buildings in Shah Alam, Selangor was investigated. The concentrations of carbon monoxide (CO), carbon dioxide (CO2), and particulate matters (PM10) in outdoor and indoor of the houses were determined for 8 hour period. The mean concentration of CO, CO2 and PM10 indoor was in the range 0.24–0.31 ppm, 437.18–549.57 ppm and 94.00–124.00 μg/m3 respectively. The results indicated that all of the average indoor concentrations of CO, CO2, and PM10 were below the limit of Malaysian guideline standards. The indoor/outdoor concentration ratios of all air pollutants were found to be below one, except for CO2 which seems to be affected by outdoor sources of origin.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信