M. Qawaqzeh, Olha Sotnik, O. Miroshnyk, S. Halko, Oleksii Sotnik, Yurii Khandola
{"title":"为市政和家庭供电的农村电网功率因数水平下降的后果计算","authors":"M. Qawaqzeh, Olha Sotnik, O. Miroshnyk, S. Halko, Oleksii Sotnik, Yurii Khandola","doi":"10.1109/MEES58014.2022.10005736","DOIUrl":null,"url":null,"abstract":"Comparative calculations of the load of a power transformer with a capacity of 100 kV.A and the carrying capacity, voltage and losses of electricity on a power transmission line of 0.4 kV in the village of Lutovinovka of the Kozelshchansky district branch of Poltavaoblenergo are carried out, taking into account the reduced value of the power factor and without taking into account the power factor (the existing method of calculation power loss). The refined values of the power factor showed that when calculating the current and voltage losses in the line sections, the calculations will be underestimated compared to the existing losses.","PeriodicalId":244144,"journal":{"name":"2022 IEEE 4th International Conference on Modern Electrical and Energy System (MEES)","volume":"148 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Calculation of the Consequences of a Decrease in the Power Factor Level in Rural Electrical Networks Supplying Municipal and Household Electrical Consumers\",\"authors\":\"M. Qawaqzeh, Olha Sotnik, O. Miroshnyk, S. Halko, Oleksii Sotnik, Yurii Khandola\",\"doi\":\"10.1109/MEES58014.2022.10005736\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Comparative calculations of the load of a power transformer with a capacity of 100 kV.A and the carrying capacity, voltage and losses of electricity on a power transmission line of 0.4 kV in the village of Lutovinovka of the Kozelshchansky district branch of Poltavaoblenergo are carried out, taking into account the reduced value of the power factor and without taking into account the power factor (the existing method of calculation power loss). The refined values of the power factor showed that when calculating the current and voltage losses in the line sections, the calculations will be underestimated compared to the existing losses.\",\"PeriodicalId\":244144,\"journal\":{\"name\":\"2022 IEEE 4th International Conference on Modern Electrical and Energy System (MEES)\",\"volume\":\"148 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE 4th International Conference on Modern Electrical and Energy System (MEES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MEES58014.2022.10005736\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 4th International Conference on Modern Electrical and Energy System (MEES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEES58014.2022.10005736","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Calculation of the Consequences of a Decrease in the Power Factor Level in Rural Electrical Networks Supplying Municipal and Household Electrical Consumers
Comparative calculations of the load of a power transformer with a capacity of 100 kV.A and the carrying capacity, voltage and losses of electricity on a power transmission line of 0.4 kV in the village of Lutovinovka of the Kozelshchansky district branch of Poltavaoblenergo are carried out, taking into account the reduced value of the power factor and without taking into account the power factor (the existing method of calculation power loss). The refined values of the power factor showed that when calculating the current and voltage losses in the line sections, the calculations will be underestimated compared to the existing losses.