{"title":"LC电池剩余直流电的评价","authors":"Y. Nakazono, T. Takagi, A. Sawada, S. Naemura","doi":"10.1109/ASID.1999.762750","DOIUrl":null,"url":null,"abstract":"Residual DC phenomenon is discussed based on the simulation with equivalent circuit of LC cell and experiments for three kind of cells which has different alignment layer with different specific resistivity values. Interfacial and dipole polarization of multi layered dielectrics is caused by DC voltage application. The r-DC observed in short time range (few min.) can be explained by this polarization. Even after the interfacial polarization is relaxed, however, some amount of ions, which moved close to the interface between the LC and the alignment layers, remain for a longer time due to an adsorption phenomenon. The observed r-DC voltage for a longer time range, typically over 1 hour, can be explained by this model of ion adsorption.","PeriodicalId":170859,"journal":{"name":"Proceedings of 5th Asian Symposium on Information Display. ASID '99 (IEEE Cat. No.99EX291)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Evaluation of residual DC of LC cell\",\"authors\":\"Y. Nakazono, T. Takagi, A. Sawada, S. Naemura\",\"doi\":\"10.1109/ASID.1999.762750\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Residual DC phenomenon is discussed based on the simulation with equivalent circuit of LC cell and experiments for three kind of cells which has different alignment layer with different specific resistivity values. Interfacial and dipole polarization of multi layered dielectrics is caused by DC voltage application. The r-DC observed in short time range (few min.) can be explained by this polarization. Even after the interfacial polarization is relaxed, however, some amount of ions, which moved close to the interface between the LC and the alignment layers, remain for a longer time due to an adsorption phenomenon. The observed r-DC voltage for a longer time range, typically over 1 hour, can be explained by this model of ion adsorption.\",\"PeriodicalId\":170859,\"journal\":{\"name\":\"Proceedings of 5th Asian Symposium on Information Display. ASID '99 (IEEE Cat. No.99EX291)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-03-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 5th Asian Symposium on Information Display. ASID '99 (IEEE Cat. No.99EX291)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ASID.1999.762750\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 5th Asian Symposium on Information Display. ASID '99 (IEEE Cat. No.99EX291)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASID.1999.762750","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

通过对LC电池等效电路的仿真,以及对三种具有不同取向层和不同比电阻率值的电池的实验,讨论了剩余直流现象。多层介质的界面极化和偶极极化是由直流电压作用引起的。在短时间范围内(几分钟)观察到的r-DC可以用这种极化来解释。然而,即使在界面极化放松后,由于吸附现象,在LC和取向层之间的界面附近移动的一些离子仍停留较长时间。观察到的r-DC电压在较长的时间范围内,通常超过1小时,可以用这种离子吸附模型来解释。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of residual DC of LC cell
Residual DC phenomenon is discussed based on the simulation with equivalent circuit of LC cell and experiments for three kind of cells which has different alignment layer with different specific resistivity values. Interfacial and dipole polarization of multi layered dielectrics is caused by DC voltage application. The r-DC observed in short time range (few min.) can be explained by this polarization. Even after the interfacial polarization is relaxed, however, some amount of ions, which moved close to the interface between the LC and the alignment layers, remain for a longer time due to an adsorption phenomenon. The observed r-DC voltage for a longer time range, typically over 1 hour, can be explained by this model of ion adsorption.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信