万型横向磁场触点中断特性研究

Li Zhao, S. Xiu, Jiashuo Cui, Zepeng Chen, Mengru Li, Bo Yuan
{"title":"万型横向磁场触点中断特性研究","authors":"Li Zhao, S. Xiu, Jiashuo Cui, Zepeng Chen, Mengru Li, Bo Yuan","doi":"10.1109/ICEPE-ST.2019.8928837","DOIUrl":null,"url":null,"abstract":"With the outstanding advantages of short current path, small on-resistance and low cost, the transverse magnetic field (TMF) contacts have been widely applied in medium voltage power systems. In this paper, the vacuum arc experimental system was established using the inductor-capacitor (LC) oscillation circuit, wan-type transverse magnetic field contacts were installed in the demountable vacuum chamber, and the vacuum arc behavior was recorded by the high-speed video camera to research arc characteristics during the arcing process, which including the initial ignition stage, the expansion stage, the arc motion stage and the diffuse stage. In addition, the impact of opening moments was analyzed, and the relationship between arc voltage and arc appearances was summarized. It was found that the change of arc column number in the expansion stage would cause sudden fluctuations of the arc voltage, and unstable arc motion and plasma splash would give rise to arc voltage noise. Then tested contacts were installed into the vacuum interrupters with the same structure and size, the interrupting characteristic experiments of vacuum interrupters with TMF contacts and vacuum interrupters with axial magnetic field (AMF) contacts were completed, and the power frequency withstand tests and the lightning impulse tests of the vacuum interrupters were carried out. The results showed that the wan-type TMF contacts used in this paper had equivalent interruption characteristics as the six-slot cup-shaped AMF contacts.","PeriodicalId":392306,"journal":{"name":"2019 5th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","volume":"90 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research on the Interruption Characteristics of Wan-type Transverse Magnetic Field Contacts\",\"authors\":\"Li Zhao, S. Xiu, Jiashuo Cui, Zepeng Chen, Mengru Li, Bo Yuan\",\"doi\":\"10.1109/ICEPE-ST.2019.8928837\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With the outstanding advantages of short current path, small on-resistance and low cost, the transverse magnetic field (TMF) contacts have been widely applied in medium voltage power systems. In this paper, the vacuum arc experimental system was established using the inductor-capacitor (LC) oscillation circuit, wan-type transverse magnetic field contacts were installed in the demountable vacuum chamber, and the vacuum arc behavior was recorded by the high-speed video camera to research arc characteristics during the arcing process, which including the initial ignition stage, the expansion stage, the arc motion stage and the diffuse stage. In addition, the impact of opening moments was analyzed, and the relationship between arc voltage and arc appearances was summarized. It was found that the change of arc column number in the expansion stage would cause sudden fluctuations of the arc voltage, and unstable arc motion and plasma splash would give rise to arc voltage noise. Then tested contacts were installed into the vacuum interrupters with the same structure and size, the interrupting characteristic experiments of vacuum interrupters with TMF contacts and vacuum interrupters with axial magnetic field (AMF) contacts were completed, and the power frequency withstand tests and the lightning impulse tests of the vacuum interrupters were carried out. The results showed that the wan-type TMF contacts used in this paper had equivalent interruption characteristics as the six-slot cup-shaped AMF contacts.\",\"PeriodicalId\":392306,\"journal\":{\"name\":\"2019 5th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)\",\"volume\":\"90 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 5th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEPE-ST.2019.8928837\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 5th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEPE-ST.2019.8928837","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

横向磁场触点具有电流路径短、导通电阻小、成本低等突出优点,在中压电力系统中得到了广泛的应用。本文采用电感-电容振荡电路(LC)建立了真空电弧实验系统,在可拆卸真空室中安装万向横向磁场触点,通过高速摄像机记录真空电弧的行为,研究电弧在初始点火阶段、膨胀阶段、电弧运动阶段和扩散阶段的电弧特性。此外,还分析了开弧力矩的影响,总结了电弧电压与电弧形态的关系。研究发现,膨胀阶段电弧柱数的变化会引起电弧电压的突然波动,不稳定的电弧运动和等离子体飞溅会引起电弧电压噪声。将测试过的触点安装在相同结构和尺寸的真空灭弧器中,完成了带TMF触点的真空灭弧器和带轴向磁场(AMF)触点的真空灭弧器的灭弧特性实验,并对真空灭弧器进行了工频耐压试验和雷击试验。结果表明,本文采用的万用型TMF触点与六槽杯形AMF触点具有等效的中断特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Research on the Interruption Characteristics of Wan-type Transverse Magnetic Field Contacts
With the outstanding advantages of short current path, small on-resistance and low cost, the transverse magnetic field (TMF) contacts have been widely applied in medium voltage power systems. In this paper, the vacuum arc experimental system was established using the inductor-capacitor (LC) oscillation circuit, wan-type transverse magnetic field contacts were installed in the demountable vacuum chamber, and the vacuum arc behavior was recorded by the high-speed video camera to research arc characteristics during the arcing process, which including the initial ignition stage, the expansion stage, the arc motion stage and the diffuse stage. In addition, the impact of opening moments was analyzed, and the relationship between arc voltage and arc appearances was summarized. It was found that the change of arc column number in the expansion stage would cause sudden fluctuations of the arc voltage, and unstable arc motion and plasma splash would give rise to arc voltage noise. Then tested contacts were installed into the vacuum interrupters with the same structure and size, the interrupting characteristic experiments of vacuum interrupters with TMF contacts and vacuum interrupters with axial magnetic field (AMF) contacts were completed, and the power frequency withstand tests and the lightning impulse tests of the vacuum interrupters were carried out. The results showed that the wan-type TMF contacts used in this paper had equivalent interruption characteristics as the six-slot cup-shaped AMF contacts.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信