K. Ngamsanroaj, S. Premrudeepreechacharn, S. Chimklai
{"title":"泰国湄莫至塔塔哥500千伏线路单线接地故障二次消弧的模拟研究","authors":"K. Ngamsanroaj, S. Premrudeepreechacharn, S. Chimklai","doi":"10.1109/UPEC.2008.4651524","DOIUrl":null,"url":null,"abstract":"Successful operation of a power system depends largely on the ability to provide reliable and uninterrupted service to the loads. Single phase switching has become an increasingly more viable approach to the operation of EHV systems in recent years. Indeed, single phase reclosing, if successful, represents a significant step in improving system performance and is an attractive, economical means of obtaining acceptable transient stability with fewer lines. Single phase reclosing has the additional benefits of reducing switching overvoltages. This paper describes the simulation study of secondary arc extinction due to single line to ground fault and then clearing the faulted line. The work is performed by EMTP on the Thailand 500 kV transmission line from Mae Moh to Tha Ta Ko. Various responses of simulation results are presented.","PeriodicalId":287461,"journal":{"name":"2008 43rd International Universities Power Engineering Conference","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Simulation study of the secondary arc extinction due to single line to ground fault on the Thailand 500 kV Line from Mae Moh to Tha Ta Ko\",\"authors\":\"K. Ngamsanroaj, S. Premrudeepreechacharn, S. Chimklai\",\"doi\":\"10.1109/UPEC.2008.4651524\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Successful operation of a power system depends largely on the ability to provide reliable and uninterrupted service to the loads. Single phase switching has become an increasingly more viable approach to the operation of EHV systems in recent years. Indeed, single phase reclosing, if successful, represents a significant step in improving system performance and is an attractive, economical means of obtaining acceptable transient stability with fewer lines. Single phase reclosing has the additional benefits of reducing switching overvoltages. This paper describes the simulation study of secondary arc extinction due to single line to ground fault and then clearing the faulted line. The work is performed by EMTP on the Thailand 500 kV transmission line from Mae Moh to Tha Ta Ko. Various responses of simulation results are presented.\",\"PeriodicalId\":287461,\"journal\":{\"name\":\"2008 43rd International Universities Power Engineering Conference\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-12-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 43rd International Universities Power Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UPEC.2008.4651524\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 43rd International Universities Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2008.4651524","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
摘要
电力系统的成功运行在很大程度上取决于向负载提供可靠和不间断服务的能力。近年来,单相开关已成为一种越来越可行的超高压系统运行方式。事实上,单相重合闸如果成功,将是改善系统性能的重要一步,也是一种有吸引力的、经济的方法,可以用更少的线路获得可接受的暂态稳定性。单相重合闸具有降低开关过电压的额外好处。本文对单线接地故障后再对故障线进行清理的二次消弧模拟研究。这项工作由EMTP在泰国从Mae Moh到Tha Ta Ko的500千伏输电线路上进行。给出了仿真结果的各种响应。
Simulation study of the secondary arc extinction due to single line to ground fault on the Thailand 500 kV Line from Mae Moh to Tha Ta Ko
Successful operation of a power system depends largely on the ability to provide reliable and uninterrupted service to the loads. Single phase switching has become an increasingly more viable approach to the operation of EHV systems in recent years. Indeed, single phase reclosing, if successful, represents a significant step in improving system performance and is an attractive, economical means of obtaining acceptable transient stability with fewer lines. Single phase reclosing has the additional benefits of reducing switching overvoltages. This paper describes the simulation study of secondary arc extinction due to single line to ground fault and then clearing the faulted line. The work is performed by EMTP on the Thailand 500 kV transmission line from Mae Moh to Tha Ta Ko. Various responses of simulation results are presented.