M. Ferreira, J. Bierlich, J. Kobelke, J. Santos, O. Frazão
{"title":"基于微球阵列的温度传感法布里-珀罗干涉仪","authors":"M. Ferreira, J. Bierlich, J. Kobelke, J. Santos, O. Frazão","doi":"10.1117/12.2275658","DOIUrl":null,"url":null,"abstract":"A Fabry-Perot interferometer based on an array of soda-lime glass microspheres is proposed for temperature sensing. The microspheres are introduced in a hollow-core silica tube using a tapered fiber tip. After the insertion of each microsphere the sensor is subjected to temperature measurements. The sensor exhibits non-linear behavior and a dependence on the number of microspheres is observed. A maximum sensitivity of 11.13 pm/°C is achieved, when there is only one microsphere inside the capillary structure.","PeriodicalId":150522,"journal":{"name":"Applications of Optics and Photonics","volume":"120 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Fabry-Perot interferometer based on array of microspheres for temperature sensing\",\"authors\":\"M. Ferreira, J. Bierlich, J. Kobelke, J. Santos, O. Frazão\",\"doi\":\"10.1117/12.2275658\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A Fabry-Perot interferometer based on an array of soda-lime glass microspheres is proposed for temperature sensing. The microspheres are introduced in a hollow-core silica tube using a tapered fiber tip. After the insertion of each microsphere the sensor is subjected to temperature measurements. The sensor exhibits non-linear behavior and a dependence on the number of microspheres is observed. A maximum sensitivity of 11.13 pm/°C is achieved, when there is only one microsphere inside the capillary structure.\",\"PeriodicalId\":150522,\"journal\":{\"name\":\"Applications of Optics and Photonics\",\"volume\":\"120 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-08-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applications of Optics and Photonics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2275658\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applications of Optics and Photonics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2275658","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fabry-Perot interferometer based on array of microspheres for temperature sensing
A Fabry-Perot interferometer based on an array of soda-lime glass microspheres is proposed for temperature sensing. The microspheres are introduced in a hollow-core silica tube using a tapered fiber tip. After the insertion of each microsphere the sensor is subjected to temperature measurements. The sensor exhibits non-linear behavior and a dependence on the number of microspheres is observed. A maximum sensitivity of 11.13 pm/°C is achieved, when there is only one microsphere inside the capillary structure.