A. Yusuf, A. Amoo, U. Aliyu, M. W. Mustafa, A. Zin
{"title":"电力变压器的磁致伸缩评估(以包奇变电站30/40MVA、132/ 33kv变压器为例)","authors":"A. Yusuf, A. Amoo, U. Aliyu, M. W. Mustafa, A. Zin","doi":"10.1109/PEOCO.2012.6230845","DOIUrl":null,"url":null,"abstract":"A lot of things determine the life expectancy of a transformer such as overheating due to triplen harmonics, unbalanced loading, vibro-acoustic noise and so on. For this reason, this paper presents the investigation carried out on the magnetostrictive sound of Bauchi, 30/40 MVA, 132/33 KV substation transformer. Readings were taken using standard audio recording instrument for various loading and voltage conditions in the mornings, afternoons and nights for six days and the offline assessment was carried out using digital spectrum analyzer. However, no access could be gained to the variation of certain important parameters, like changing of core dimensions, loosing or tightening of core and so on, for the substation transformer in-situ in the substation hence separate laboratory test transformers were used in the assessment of the effect of core damping pressure, construction looseness and transformer saturation on the vibro-acoustic noise. Conclusively, increasing the operation voltage of transformer tends to produce more magnetostriction effect while loosening core lamination increases the energy losses.","PeriodicalId":138236,"journal":{"name":"2012 IEEE International Power Engineering and Optimization Conference Melaka, Malaysia","volume":"293 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Magnetostriction assessment of power transformer (a case study of 30/40MVA, 132/33 kV transformer at Bauchi substation)\",\"authors\":\"A. Yusuf, A. Amoo, U. Aliyu, M. W. Mustafa, A. Zin\",\"doi\":\"10.1109/PEOCO.2012.6230845\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A lot of things determine the life expectancy of a transformer such as overheating due to triplen harmonics, unbalanced loading, vibro-acoustic noise and so on. For this reason, this paper presents the investigation carried out on the magnetostrictive sound of Bauchi, 30/40 MVA, 132/33 KV substation transformer. Readings were taken using standard audio recording instrument for various loading and voltage conditions in the mornings, afternoons and nights for six days and the offline assessment was carried out using digital spectrum analyzer. However, no access could be gained to the variation of certain important parameters, like changing of core dimensions, loosing or tightening of core and so on, for the substation transformer in-situ in the substation hence separate laboratory test transformers were used in the assessment of the effect of core damping pressure, construction looseness and transformer saturation on the vibro-acoustic noise. Conclusively, increasing the operation voltage of transformer tends to produce more magnetostriction effect while loosening core lamination increases the energy losses.\",\"PeriodicalId\":138236,\"journal\":{\"name\":\"2012 IEEE International Power Engineering and Optimization Conference Melaka, Malaysia\",\"volume\":\"293 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-06-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE International Power Engineering and Optimization Conference Melaka, Malaysia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEOCO.2012.6230845\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE International Power Engineering and Optimization Conference Melaka, Malaysia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEOCO.2012.6230845","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Magnetostriction assessment of power transformer (a case study of 30/40MVA, 132/33 kV transformer at Bauchi substation)
A lot of things determine the life expectancy of a transformer such as overheating due to triplen harmonics, unbalanced loading, vibro-acoustic noise and so on. For this reason, this paper presents the investigation carried out on the magnetostrictive sound of Bauchi, 30/40 MVA, 132/33 KV substation transformer. Readings were taken using standard audio recording instrument for various loading and voltage conditions in the mornings, afternoons and nights for six days and the offline assessment was carried out using digital spectrum analyzer. However, no access could be gained to the variation of certain important parameters, like changing of core dimensions, loosing or tightening of core and so on, for the substation transformer in-situ in the substation hence separate laboratory test transformers were used in the assessment of the effect of core damping pressure, construction looseness and transformer saturation on the vibro-acoustic noise. Conclusively, increasing the operation voltage of transformer tends to produce more magnetostriction effect while loosening core lamination increases the energy losses.