{"title":"电流三倍整流型ZVS三相全桥DC/DC变换器的纠错操作","authors":"W. Tian, Lei Wang, Jiawen Yu, S. Liao, Qian Zhou","doi":"10.1109/peas53589.2021.9628623","DOIUrl":null,"url":null,"abstract":"Current-tripler-rectifier ZVS three-phase full-bridge DC/DC converter (CTR-ZVS-FB converter) is a potential alternative for high-power applications due to its desirable characteristics of compact, efficient, high current capability, etc. In some cases, the failure of the power switch results in a converter shutdown and affects the reliability of the entire system. Therefore, this article presents a new remedial fault-tolerant operation for the CTR-ZVS-FB converter. During the remedial working mode, the inductor current, ZVS Soft-Switching Regions, and loss of duty cycle are analyzed. Moreover, this paper simulates the heavy loads of the converter under the remedial fault-tolerant operation. Results convincingly indicate that the proposed control is efficient and capable of running the system during the faults with a slight increase in the inductor current.","PeriodicalId":268264,"journal":{"name":"2021 IEEE 1st International Power Electronics and Application Symposium (PEAS)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Remedial Fault-Tolerant Operation of a Current-Tripler-Rectifier ZVS Three-Phase Full-Bridge DC/DC Converter\",\"authors\":\"W. Tian, Lei Wang, Jiawen Yu, S. Liao, Qian Zhou\",\"doi\":\"10.1109/peas53589.2021.9628623\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Current-tripler-rectifier ZVS three-phase full-bridge DC/DC converter (CTR-ZVS-FB converter) is a potential alternative for high-power applications due to its desirable characteristics of compact, efficient, high current capability, etc. In some cases, the failure of the power switch results in a converter shutdown and affects the reliability of the entire system. Therefore, this article presents a new remedial fault-tolerant operation for the CTR-ZVS-FB converter. During the remedial working mode, the inductor current, ZVS Soft-Switching Regions, and loss of duty cycle are analyzed. Moreover, this paper simulates the heavy loads of the converter under the remedial fault-tolerant operation. Results convincingly indicate that the proposed control is efficient and capable of running the system during the faults with a slight increase in the inductor current.\",\"PeriodicalId\":268264,\"journal\":{\"name\":\"2021 IEEE 1st International Power Electronics and Application Symposium (PEAS)\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE 1st International Power Electronics and Application Symposium (PEAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/peas53589.2021.9628623\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 1st International Power Electronics and Application Symposium (PEAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/peas53589.2021.9628623","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电流三倍整流ZVS三相全桥DC/DC变换器(CTR-ZVS-FB变换器)由于其紧凑、高效、高电流能力等理想特性,是高功率应用的潜在替代方案。在某些情况下,电源开关的故障会导致变流器停机,影响整个系统的可靠性。因此,本文提出了一种新的cr - zvs - fb变换器的容错补救操作。在补救工作模式下,分析了电感电流、ZVS软开关区域和占空比损耗。此外,本文还对变流器在容错补救运行下的大负荷进行了仿真。结果令人信服地表明,所提出的控制是有效的,并且能够在故障期间运行系统,电感电流略有增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Remedial Fault-Tolerant Operation of a Current-Tripler-Rectifier ZVS Three-Phase Full-Bridge DC/DC Converter
Current-tripler-rectifier ZVS three-phase full-bridge DC/DC converter (CTR-ZVS-FB converter) is a potential alternative for high-power applications due to its desirable characteristics of compact, efficient, high current capability, etc. In some cases, the failure of the power switch results in a converter shutdown and affects the reliability of the entire system. Therefore, this article presents a new remedial fault-tolerant operation for the CTR-ZVS-FB converter. During the remedial working mode, the inductor current, ZVS Soft-Switching Regions, and loss of duty cycle are analyzed. Moreover, this paper simulates the heavy loads of the converter under the remedial fault-tolerant operation. Results convincingly indicate that the proposed control is efficient and capable of running the system during the faults with a slight increase in the inductor current.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信