基于积分滑模控制的并网光伏逆变器鲁棒连续非线性预测控制器(CNMPC)

B. Ayalew, A. Yahaya, Ahmed Al Durra
{"title":"基于积分滑模控制的并网光伏逆变器鲁棒连续非线性预测控制器(CNMPC)","authors":"B. Ayalew, A. Yahaya, Ahmed Al Durra","doi":"10.1109/SPIES48661.2020.9242546","DOIUrl":null,"url":null,"abstract":"This paper presents robust continuous non linear control for grid tied PV inverter by combining model predictive control (CNMPC) and integral sliding mode control (ISMC). Based on cascaded control structure, combination of CNMPC and ISMC is proposed for both outer and inner control loops. Low pass filter is used to extract the equivalent of the discontinuous switching of ISMC so that the outputs of ISMC and CNMPC are added. Moreover, it is mathematically illustrated that the equivalent of ISMC is actually the same as the magnitude of disturbance. The performance of the proposed controller is verified through series of simulation tests. The combined controller shows robust response for parameter uncertainty and external disturbances such as dc current from PV. It is also shown that the grid current total harmonics distortion(THD) is within the international standards.","PeriodicalId":244426,"journal":{"name":"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)","volume":"258 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Robust Continuous Nonlinear Predictive Controller (CNMPC) via Integral Sliding Mode Control (ISMC) for Grid-Tied PV Inverter\",\"authors\":\"B. Ayalew, A. Yahaya, Ahmed Al Durra\",\"doi\":\"10.1109/SPIES48661.2020.9242546\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents robust continuous non linear control for grid tied PV inverter by combining model predictive control (CNMPC) and integral sliding mode control (ISMC). Based on cascaded control structure, combination of CNMPC and ISMC is proposed for both outer and inner control loops. Low pass filter is used to extract the equivalent of the discontinuous switching of ISMC so that the outputs of ISMC and CNMPC are added. Moreover, it is mathematically illustrated that the equivalent of ISMC is actually the same as the magnitude of disturbance. The performance of the proposed controller is verified through series of simulation tests. The combined controller shows robust response for parameter uncertainty and external disturbances such as dc current from PV. It is also shown that the grid current total harmonics distortion(THD) is within the international standards.\",\"PeriodicalId\":244426,\"journal\":{\"name\":\"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)\",\"volume\":\"258 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SPIES48661.2020.9242546\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPIES48661.2020.9242546","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

将模型预测控制(CNMPC)与积分滑模控制(ISMC)相结合,提出了并网光伏逆变器的鲁棒连续非线性控制方法。基于级联控制结构,提出了CNMPC和ISMC相结合的外、内控制回路。利用低通滤波器提取ISMC断续开关的当量,将ISMC和CNMPC的输出相加。此外,从数学上说明了ISMC的等效实际上与扰动的大小相同。通过一系列的仿真试验验证了所提控制器的性能。该组合控制器对参数不确定性和外部干扰(如来自PV的直流电流)具有鲁棒性响应。结果表明,电网电流总谐波失真(THD)符合国际标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Robust Continuous Nonlinear Predictive Controller (CNMPC) via Integral Sliding Mode Control (ISMC) for Grid-Tied PV Inverter
This paper presents robust continuous non linear control for grid tied PV inverter by combining model predictive control (CNMPC) and integral sliding mode control (ISMC). Based on cascaded control structure, combination of CNMPC and ISMC is proposed for both outer and inner control loops. Low pass filter is used to extract the equivalent of the discontinuous switching of ISMC so that the outputs of ISMC and CNMPC are added. Moreover, it is mathematically illustrated that the equivalent of ISMC is actually the same as the magnitude of disturbance. The performance of the proposed controller is verified through series of simulation tests. The combined controller shows robust response for parameter uncertainty and external disturbances such as dc current from PV. It is also shown that the grid current total harmonics distortion(THD) is within the international standards.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信