{"title":"将传输线理论应用于PWM逆变器引起的电机电压应力频域分析","authors":"G. Oriti, A. Julian","doi":"10.1109/IAS.2004.1348742","DOIUrl":null,"url":null,"abstract":"The innovative contribution of this paper is the application of a frequency domain model based on the transmission line modeling techniques for a four conductor cable bundle without the assumption of lossless lines. A thorough documentation of the mathematical model is included. Laboratory measurements validate the model which predicts the peak motor terminal voltage caused by: 1) different motor cable sizes and geometry 2) variations of the inverter dv/dt 3) variations of the voltage step size applied to the cable 4) termination networks inserted at the motor terminals to control the dv/dt.","PeriodicalId":131410,"journal":{"name":"Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.","volume":"122 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":"{\"title\":\"Application of the transmission line theory to the frequency domain analysis of the motor voltage stress caused by PWM inverters\",\"authors\":\"G. Oriti, A. Julian\",\"doi\":\"10.1109/IAS.2004.1348742\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The innovative contribution of this paper is the application of a frequency domain model based on the transmission line modeling techniques for a four conductor cable bundle without the assumption of lossless lines. A thorough documentation of the mathematical model is included. Laboratory measurements validate the model which predicts the peak motor terminal voltage caused by: 1) different motor cable sizes and geometry 2) variations of the inverter dv/dt 3) variations of the voltage step size applied to the cable 4) termination networks inserted at the motor terminals to control the dv/dt.\",\"PeriodicalId\":131410,\"journal\":{\"name\":\"Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.\",\"volume\":\"122 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"20\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.2004.1348742\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2004.1348742","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Application of the transmission line theory to the frequency domain analysis of the motor voltage stress caused by PWM inverters
The innovative contribution of this paper is the application of a frequency domain model based on the transmission line modeling techniques for a four conductor cable bundle without the assumption of lossless lines. A thorough documentation of the mathematical model is included. Laboratory measurements validate the model which predicts the peak motor terminal voltage caused by: 1) different motor cable sizes and geometry 2) variations of the inverter dv/dt 3) variations of the voltage step size applied to the cable 4) termination networks inserted at the motor terminals to control the dv/dt.