PRIME PLC调制解调器在印度配电变压器上的性能评估

Konark Sharma, L. Saini
{"title":"PRIME PLC调制解调器在印度配电变压器上的性能评估","authors":"Konark Sharma, L. Saini","doi":"10.1049/PBPO132E_CH13","DOIUrl":null,"url":null,"abstract":"The past few years have witnessed a tremendous development in powerline intelligent metering evolution (PRIME) technology for high speed data communication across medium voltage (MV) and low voltage (LV) transmission/distribution networks based smart grid (SG) applications. PRIME PLC (PRIME power-line communication) technology also elucidates the importance of employing robust modulation schemes across distribution-transformers and motivates research in this direction. Indeed, the aim of the chapter is to investigate PRIME channel measurements through MV/LV distribution transformers by implementing experimental tests to analyze the signal-to-noise ratio (SNR), bit error rate (BER) and packet error rate (PER) performance of differential binary phase shift keying (DBPSK), differential quadrature phase shift keying (DQPSK) and eight-ary differential phase shift keying (D8PSK) modulation schemes over multipath PLC channels in Indian context.","PeriodicalId":282284,"journal":{"name":"Power Line Communication Systems for Smart Grids","volume":"200 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance evaluation of PRIME PLC modems over distribution transformers in Indian context\",\"authors\":\"Konark Sharma, L. Saini\",\"doi\":\"10.1049/PBPO132E_CH13\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The past few years have witnessed a tremendous development in powerline intelligent metering evolution (PRIME) technology for high speed data communication across medium voltage (MV) and low voltage (LV) transmission/distribution networks based smart grid (SG) applications. PRIME PLC (PRIME power-line communication) technology also elucidates the importance of employing robust modulation schemes across distribution-transformers and motivates research in this direction. Indeed, the aim of the chapter is to investigate PRIME channel measurements through MV/LV distribution transformers by implementing experimental tests to analyze the signal-to-noise ratio (SNR), bit error rate (BER) and packet error rate (PER) performance of differential binary phase shift keying (DBPSK), differential quadrature phase shift keying (DQPSK) and eight-ary differential phase shift keying (D8PSK) modulation schemes over multipath PLC channels in Indian context.\",\"PeriodicalId\":282284,\"journal\":{\"name\":\"Power Line Communication Systems for Smart Grids\",\"volume\":\"200 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Power Line Communication Systems for Smart Grids\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1049/PBPO132E_CH13\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Power Line Communication Systems for Smart Grids","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1049/PBPO132E_CH13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在过去的几年中,电力线智能计量演进(PRIME)技术在基于智能电网(SG)应用的中压(MV)和低压(LV)输配电网络中的高速数据通信方面取得了巨大的发展。PRIME PLC (PRIME电力线通信)技术也阐明了跨配电变压器采用鲁棒调制方案的重要性,并激励了这一方向的研究。事实上,本章的目的是通过中压/低压配电变压器研究PRIME通道测量,通过实施实验测试来分析印度多径PLC信道上差分二进制相移键控(DBPSK)、差分正交相移键控(DQPSK)和八进差分相移键控(D8PSK)调制方案的信噪比(SNR)、误码率(BER)和分组误码率(PER)性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance evaluation of PRIME PLC modems over distribution transformers in Indian context
The past few years have witnessed a tremendous development in powerline intelligent metering evolution (PRIME) technology for high speed data communication across medium voltage (MV) and low voltage (LV) transmission/distribution networks based smart grid (SG) applications. PRIME PLC (PRIME power-line communication) technology also elucidates the importance of employing robust modulation schemes across distribution-transformers and motivates research in this direction. Indeed, the aim of the chapter is to investigate PRIME channel measurements through MV/LV distribution transformers by implementing experimental tests to analyze the signal-to-noise ratio (SNR), bit error rate (BER) and packet error rate (PER) performance of differential binary phase shift keying (DBPSK), differential quadrature phase shift keying (DQPSK) and eight-ary differential phase shift keying (D8PSK) modulation schemes over multipath PLC channels in Indian context.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信