{"title":"外推室测量的电子深度吸收剂量分布。","authors":"H Järvinen","doi":"10.3109/02841867709134305","DOIUrl":null,"url":null,"abstract":"<p><p>An extrapolation ionization chamber was constructed and used to measure depth absorbed dose distributions of electron beams from the electron therapy units in Finland. Particular attention was payed to the surface dose, the build-up region, and the energy calibration. Differences between various units are discussed.</p>","PeriodicalId":7139,"journal":{"name":"Acta radiologica: therapy, physics, biology","volume":"16 2","pages":"129-35"},"PeriodicalIF":0.0000,"publicationDate":"1977-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/02841867709134305","citationCount":"5","resultStr":"{\"title\":\"Extrapolation chamber measurements of electron depth absorbed dose distributions.\",\"authors\":\"H Järvinen\",\"doi\":\"10.3109/02841867709134305\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>An extrapolation ionization chamber was constructed and used to measure depth absorbed dose distributions of electron beams from the electron therapy units in Finland. Particular attention was payed to the surface dose, the build-up region, and the energy calibration. Differences between various units are discussed.</p>\",\"PeriodicalId\":7139,\"journal\":{\"name\":\"Acta radiologica: therapy, physics, biology\",\"volume\":\"16 2\",\"pages\":\"129-35\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1977-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/02841867709134305\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta radiologica: therapy, physics, biology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/02841867709134305\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica: therapy, physics, biology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/02841867709134305","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Extrapolation chamber measurements of electron depth absorbed dose distributions.
An extrapolation ionization chamber was constructed and used to measure depth absorbed dose distributions of electron beams from the electron therapy units in Finland. Particular attention was payed to the surface dose, the build-up region, and the energy calibration. Differences between various units are discussed.