{"title":"使用iv型风力发电机的海上风电场出口电缆保护","authors":"Ardavan Mohammadhassani, Nicholas Skoff, Tin Chi Nguyen, A. Mehrizi‐Sani","doi":"10.1109/CFPR57837.2023.10127019","DOIUrl":null,"url":null,"abstract":"Export cable protection for offshore wind farms (OWF) using Type-IV wind turbine generators (WTGs) is challenging due to the WTG's limited, variable, and unconventional fault-current response. Typically, line-current-differential relaying is used for primary protection and then, when communication is lost, the differential relays are backed up by distance relays. However, in presence of WTGs, distance protection is highly prone to misoperation. Therefore, this paper proposes a protection scheme that uses a loss-of-potential overcurrent logic for OWF export cables as an alternative backup protection. For this study, an experimental setup was created using a real-time digital simulator and physical relays to evaluate the performance of the proposed protection scheme using hardware-in-the-loop testing. Test results showed that the proposed scheme operated correctly under different types of faults and fault locations.","PeriodicalId":296283,"journal":{"name":"2023 76th Annual Conference for Protective Relay Engineers (CFPR)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Export Cable Protection for Offshore Wind Farms Using Type-IV Wind Turbine Generators\",\"authors\":\"Ardavan Mohammadhassani, Nicholas Skoff, Tin Chi Nguyen, A. Mehrizi‐Sani\",\"doi\":\"10.1109/CFPR57837.2023.10127019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Export cable protection for offshore wind farms (OWF) using Type-IV wind turbine generators (WTGs) is challenging due to the WTG's limited, variable, and unconventional fault-current response. Typically, line-current-differential relaying is used for primary protection and then, when communication is lost, the differential relays are backed up by distance relays. However, in presence of WTGs, distance protection is highly prone to misoperation. Therefore, this paper proposes a protection scheme that uses a loss-of-potential overcurrent logic for OWF export cables as an alternative backup protection. For this study, an experimental setup was created using a real-time digital simulator and physical relays to evaluate the performance of the proposed protection scheme using hardware-in-the-loop testing. Test results showed that the proposed scheme operated correctly under different types of faults and fault locations.\",\"PeriodicalId\":296283,\"journal\":{\"name\":\"2023 76th Annual Conference for Protective Relay Engineers (CFPR)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 76th Annual Conference for Protective Relay Engineers (CFPR)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CFPR57837.2023.10127019\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 76th Annual Conference for Protective Relay Engineers (CFPR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CFPR57837.2023.10127019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于iv型风力发电机(WTG)的有限、可变和非常规的故障电流响应,海上风电场(OWF)的出口电缆保护具有挑战性。通常,线路电流差动继电器用于初级保护,然后,当通信丢失时,差动继电器由距离继电器备份。然而,在wtg存在的情况下,距离保护极易发生误操作。因此,本文提出了一种利用OWF输出电缆的过流失电位逻辑作为备用保护的保护方案。在本研究中,使用实时数字模拟器和物理继电器创建了一个实验装置,通过硬件在环测试来评估所提出的保护方案的性能。试验结果表明,该方案在不同类型的故障和故障位置下均能正常运行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Export Cable Protection for Offshore Wind Farms Using Type-IV Wind Turbine Generators
Export cable protection for offshore wind farms (OWF) using Type-IV wind turbine generators (WTGs) is challenging due to the WTG's limited, variable, and unconventional fault-current response. Typically, line-current-differential relaying is used for primary protection and then, when communication is lost, the differential relays are backed up by distance relays. However, in presence of WTGs, distance protection is highly prone to misoperation. Therefore, this paper proposes a protection scheme that uses a loss-of-potential overcurrent logic for OWF export cables as an alternative backup protection. For this study, an experimental setup was created using a real-time digital simulator and physical relays to evaluate the performance of the proposed protection scheme using hardware-in-the-loop testing. Test results showed that the proposed scheme operated correctly under different types of faults and fault locations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信