A. Agafonov, D. S. Stepanov, A. Chebotarev, E. Shkolnikov
{"title":"充气中子管彭宁离子源电子发射参数的研究","authors":"A. Agafonov, D. S. Stepanov, A. Chebotarev, E. Shkolnikov","doi":"10.1109/APEDE.2018.8542302","DOIUrl":null,"url":null,"abstract":"The paper presents results of physical processes modeling in the gas-filled neutron tube's Pennnig-type ion source with an electron emitter. The latter is a ring-shaped thermocathode of two different configurations: an internal radius of 2 mm and external radius of 3 mm and 5 mm. The features of the discharge dynamics depending on emitted electrons currents equal to 1 mA, 10 mA and 50 mA were investigated. At a current of 1 mA for a thin and wide ring, the value of the extracted ion current and front time do not exceed 200 ¼A and 3 ¼s respectively. In the case of currents of 10 mA and 50 mA for a thin emitter ring, the ion current maximum value does not exceed 700 ¼A and front time is less than 1 ¼s. For a wide ring, the maximum value of the extracted current reaches 900 ¼A, and the front time varies from 1 μs to 3 μs.","PeriodicalId":311577,"journal":{"name":"2018 International Conference on Actual Problems of Electron Devices Engineering (APEDE)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation of the Electron Emitter Parameters of the Gas-Filled Neutron Tube's Penning Ion Source\",\"authors\":\"A. Agafonov, D. S. Stepanov, A. Chebotarev, E. Shkolnikov\",\"doi\":\"10.1109/APEDE.2018.8542302\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents results of physical processes modeling in the gas-filled neutron tube's Pennnig-type ion source with an electron emitter. The latter is a ring-shaped thermocathode of two different configurations: an internal radius of 2 mm and external radius of 3 mm and 5 mm. The features of the discharge dynamics depending on emitted electrons currents equal to 1 mA, 10 mA and 50 mA were investigated. At a current of 1 mA for a thin and wide ring, the value of the extracted ion current and front time do not exceed 200 ¼A and 3 ¼s respectively. In the case of currents of 10 mA and 50 mA for a thin emitter ring, the ion current maximum value does not exceed 700 ¼A and front time is less than 1 ¼s. For a wide ring, the maximum value of the extracted current reaches 900 ¼A, and the front time varies from 1 μs to 3 μs.\",\"PeriodicalId\":311577,\"journal\":{\"name\":\"2018 International Conference on Actual Problems of Electron Devices Engineering (APEDE)\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Conference on Actual Problems of Electron Devices Engineering (APEDE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEDE.2018.8542302\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference on Actual Problems of Electron Devices Engineering (APEDE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEDE.2018.8542302","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Investigation of the Electron Emitter Parameters of the Gas-Filled Neutron Tube's Penning Ion Source
The paper presents results of physical processes modeling in the gas-filled neutron tube's Pennnig-type ion source with an electron emitter. The latter is a ring-shaped thermocathode of two different configurations: an internal radius of 2 mm and external radius of 3 mm and 5 mm. The features of the discharge dynamics depending on emitted electrons currents equal to 1 mA, 10 mA and 50 mA were investigated. At a current of 1 mA for a thin and wide ring, the value of the extracted ion current and front time do not exceed 200 ¼A and 3 ¼s respectively. In the case of currents of 10 mA and 50 mA for a thin emitter ring, the ion current maximum value does not exceed 700 ¼A and front time is less than 1 ¼s. For a wide ring, the maximum value of the extracted current reaches 900 ¼A, and the front time varies from 1 μs to 3 μs.