紧凑型局部监控系统专为电力变压器监控过程而设计

Sacerdotianu Dumitru, Hurezeanu Iulian, Purcaru Ion
{"title":"紧凑型局部监控系统专为电力变压器监控过程而设计","authors":"Sacerdotianu Dumitru, Hurezeanu Iulian, Purcaru Ion","doi":"10.1109/UPEC.2014.6934813","DOIUrl":null,"url":null,"abstract":"The reliability of transformer units and extending their life depend greatly on the degree of monitoring of their functional parameters with a view to determining the proper predictive maintenance measures, according to their interpretation. The achievements presented in this paper are the result of continuous upgrading which consisted in: increasing calculation accuracy, replacing the fixed point calculation by calculation in floating point, increasing calculation accuracy by replacing 10-byte CAN with 16-byte CAN, increasing the speed of acquisition-calculation by allocating the acquisition and calculation functions, increasing the sampling rate, increasing the speed and security of data transmission from the local monitoring system to the central processing unit by introducing the fiber optic support, increasing the data storage space on flash memory units and providing the possibility of monitoring system software configuration, depending on the monitored parameters and the reference specific elements of the application. The paper presents a compact embedded and local version with fiber optic support implementation within the circuits for processing the information in the field corresponding to the local monitoring equipment of transformer units. The presented version is of integrated equipment implemented for a power transformer monitoring system. The central unit is a single casting structure adapted for easy fastening on electric panels, overall dimensions approx. 280mm × 230mm × 100mm.","PeriodicalId":414838,"journal":{"name":"2014 49th International Universities Power Engineering Conference (UPEC)","volume":"85 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Compact local system designed for power transformer monitoring — Type MONITRA control process\",\"authors\":\"Sacerdotianu Dumitru, Hurezeanu Iulian, Purcaru Ion\",\"doi\":\"10.1109/UPEC.2014.6934813\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The reliability of transformer units and extending their life depend greatly on the degree of monitoring of their functional parameters with a view to determining the proper predictive maintenance measures, according to their interpretation. The achievements presented in this paper are the result of continuous upgrading which consisted in: increasing calculation accuracy, replacing the fixed point calculation by calculation in floating point, increasing calculation accuracy by replacing 10-byte CAN with 16-byte CAN, increasing the speed of acquisition-calculation by allocating the acquisition and calculation functions, increasing the sampling rate, increasing the speed and security of data transmission from the local monitoring system to the central processing unit by introducing the fiber optic support, increasing the data storage space on flash memory units and providing the possibility of monitoring system software configuration, depending on the monitored parameters and the reference specific elements of the application. The paper presents a compact embedded and local version with fiber optic support implementation within the circuits for processing the information in the field corresponding to the local monitoring equipment of transformer units. The presented version is of integrated equipment implemented for a power transformer monitoring system. The central unit is a single casting structure adapted for easy fastening on electric panels, overall dimensions approx. 280mm × 230mm × 100mm.\",\"PeriodicalId\":414838,\"journal\":{\"name\":\"2014 49th International Universities Power Engineering Conference (UPEC)\",\"volume\":\"85 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 49th International Universities Power Engineering Conference (UPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UPEC.2014.6934813\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 49th International Universities Power Engineering Conference (UPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2014.6934813","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

变压器机组的可靠性和延长其寿命在很大程度上取决于对其功能参数的监测程度,以便根据它们的解释确定适当的预测性维护措施。本文所取得的成果是不断升级的结果,包括:提高计算精度,用浮点计算代替定点计算,用16字节CAN代替10字节CAN来提高计算精度,通过分配采集和计算功能来提高采集计算速度,提高采样率,通过引入光纤支持来提高本地监控系统向中央处理器传输数据的速度和安全性。增加了闪存单元上的数据存储空间,并提供了监控系统软件配置的可能性,这取决于被监控的参数和应用程序的参考特定元素。本文提出了一种紧凑的嵌入式本地版本,在电路内实现光纤支持,用于处理变压器单元本地监控设备对应的现场信息。本文介绍的是一种电力变压器监测系统的集成设备。中央单元是一个单一的铸造结构,适合于易于紧固在电气面板上,整体尺寸约。280mm × 230mm × 100mm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Compact local system designed for power transformer monitoring — Type MONITRA control process
The reliability of transformer units and extending their life depend greatly on the degree of monitoring of their functional parameters with a view to determining the proper predictive maintenance measures, according to their interpretation. The achievements presented in this paper are the result of continuous upgrading which consisted in: increasing calculation accuracy, replacing the fixed point calculation by calculation in floating point, increasing calculation accuracy by replacing 10-byte CAN with 16-byte CAN, increasing the speed of acquisition-calculation by allocating the acquisition and calculation functions, increasing the sampling rate, increasing the speed and security of data transmission from the local monitoring system to the central processing unit by introducing the fiber optic support, increasing the data storage space on flash memory units and providing the possibility of monitoring system software configuration, depending on the monitored parameters and the reference specific elements of the application. The paper presents a compact embedded and local version with fiber optic support implementation within the circuits for processing the information in the field corresponding to the local monitoring equipment of transformer units. The presented version is of integrated equipment implemented for a power transformer monitoring system. The central unit is a single casting structure adapted for easy fastening on electric panels, overall dimensions approx. 280mm × 230mm × 100mm.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信