Ambu®AuraGain™作为儿科患者插管导管的临床评价:一项描述性研究

Suhoon Lim, K. Ng, S. Chaw, Ili Syazana Jamal Azmi, Mayura Hanis Ahmad Damanhuri, I. I. Shariffuddin
{"title":"Ambu®AuraGain™作为儿科患者插管导管的临床评价:一项描述性研究","authors":"Suhoon Lim, K. Ng, S. Chaw, Ili Syazana Jamal Azmi, Mayura Hanis Ahmad Damanhuri, I. I. Shariffuddin","doi":"10.35119/myja.v1i1.13","DOIUrl":null,"url":null,"abstract":"Introduction: Many paediatric difficult airway guidelines have recommended supraglottic airway devices (SGAs) as an indispensable tool in the algorithm for managing failed intubation scenarios. It is used for maintaining ventilation in a difficult or failed intubation. The newer generation SGAs can be used as intubating conduits in patients with a difficult airway. The aim of this study was to report the efficacy and safety of Ambu® AuraGain™(Ambu A/S, Ballerup, Denmark) as a conduit for intubation in paediatric patients.Methods: Local ethics approval and informed consent were obtained before patient enrolment. Sixteen patients aged 3–12 years old were recruited. Following the induction of anaesthesia and insertion of the Ambu AuraGain, fibreoptic guided intubation was performed via the SGA. The primary outcome was the time taken for successful tracheal intubation. Secondary outcomes included the number of attempts and the time required for insertion and removal of Ambu AuraGain, oropharyngeal leak pressures, fibre optic grading of glottic views, and complications from the intubation.Results: The overall success rate concerning intubation was 87.5% (14 patients), with a mean intubation time of 57.0 ± 39.4 seconds. Successful first attempt intubations were achieved in 13 patients (81.3%). The results showed easy removal of the Ambu AuraGain device with a mean SGA removal time of 27.2 ± 19.8 seconds. No significant complications occurred throughout the study.Conclusion: The Ambu AuraGain device can be considered safe and effective as a conduit for intubation in paediatric patients.","PeriodicalId":132070,"journal":{"name":"Malaysian Journal of Anaesthesiology","volume":"113 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical evaluation of Ambu® AuraGain™ as a conduit for intubation in paediatric patients: a descriptive study\",\"authors\":\"Suhoon Lim, K. Ng, S. Chaw, Ili Syazana Jamal Azmi, Mayura Hanis Ahmad Damanhuri, I. I. Shariffuddin\",\"doi\":\"10.35119/myja.v1i1.13\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Many paediatric difficult airway guidelines have recommended supraglottic airway devices (SGAs) as an indispensable tool in the algorithm for managing failed intubation scenarios. It is used for maintaining ventilation in a difficult or failed intubation. The newer generation SGAs can be used as intubating conduits in patients with a difficult airway. The aim of this study was to report the efficacy and safety of Ambu® AuraGain™(Ambu A/S, Ballerup, Denmark) as a conduit for intubation in paediatric patients.Methods: Local ethics approval and informed consent were obtained before patient enrolment. Sixteen patients aged 3–12 years old were recruited. Following the induction of anaesthesia and insertion of the Ambu AuraGain, fibreoptic guided intubation was performed via the SGA. The primary outcome was the time taken for successful tracheal intubation. Secondary outcomes included the number of attempts and the time required for insertion and removal of Ambu AuraGain, oropharyngeal leak pressures, fibre optic grading of glottic views, and complications from the intubation.Results: The overall success rate concerning intubation was 87.5% (14 patients), with a mean intubation time of 57.0 ± 39.4 seconds. Successful first attempt intubations were achieved in 13 patients (81.3%). The results showed easy removal of the Ambu AuraGain device with a mean SGA removal time of 27.2 ± 19.8 seconds. No significant complications occurred throughout the study.Conclusion: The Ambu AuraGain device can be considered safe and effective as a conduit for intubation in paediatric patients.\",\"PeriodicalId\":132070,\"journal\":{\"name\":\"Malaysian Journal of Anaesthesiology\",\"volume\":\"113 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-07-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Malaysian Journal of Anaesthesiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35119/myja.v1i1.13\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Malaysian Journal of Anaesthesiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35119/myja.v1i1.13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

导言:许多儿科困难气道指南推荐声门上气道装置(SGAs)作为管理插管失败场景的算法中不可或缺的工具。它用于在困难或插管失败时维持通气。新一代SGAs可作为气管困难患者的插管导管。本研究的目的是报告Ambu®AuraGain™(Ambu A/S, Ballerup, Denmark)作为儿科患者插管导管的有效性和安全性。方法:患者入组前获得当地伦理审批和知情同意。16名年龄在3-12岁的患者被招募。在麻醉诱导和Ambu AuraGain插入后,通过SGA进行纤维引导插管。主要观察指标为气管插管成功所需的时间。次要结果包括尝试次数和插入和取出Ambu AuraGain所需的时间,口咽漏压,声门视图的光纤分级以及插管并发症。结果:14例患者插管总成功率87.5%,平均插管时间57.0±39.4 s。首次插管成功13例(81.3%)。结果表明,Ambu AuraGain装置易于去除,平均SGA去除时间为27.2±19.8秒。在整个研究过程中没有发生明显的并发症。结论:Ambu AuraGain装置作为儿科患者插管导管是安全有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Clinical evaluation of Ambu® AuraGain™ as a conduit for intubation in paediatric patients: a descriptive study
Introduction: Many paediatric difficult airway guidelines have recommended supraglottic airway devices (SGAs) as an indispensable tool in the algorithm for managing failed intubation scenarios. It is used for maintaining ventilation in a difficult or failed intubation. The newer generation SGAs can be used as intubating conduits in patients with a difficult airway. The aim of this study was to report the efficacy and safety of Ambu® AuraGain™(Ambu A/S, Ballerup, Denmark) as a conduit for intubation in paediatric patients.Methods: Local ethics approval and informed consent were obtained before patient enrolment. Sixteen patients aged 3–12 years old were recruited. Following the induction of anaesthesia and insertion of the Ambu AuraGain, fibreoptic guided intubation was performed via the SGA. The primary outcome was the time taken for successful tracheal intubation. Secondary outcomes included the number of attempts and the time required for insertion and removal of Ambu AuraGain, oropharyngeal leak pressures, fibre optic grading of glottic views, and complications from the intubation.Results: The overall success rate concerning intubation was 87.5% (14 patients), with a mean intubation time of 57.0 ± 39.4 seconds. Successful first attempt intubations were achieved in 13 patients (81.3%). The results showed easy removal of the Ambu AuraGain device with a mean SGA removal time of 27.2 ± 19.8 seconds. No significant complications occurred throughout the study.Conclusion: The Ambu AuraGain device can be considered safe and effective as a conduit for intubation in paediatric patients.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信