Jing-hui Wang, Zun-dong Yuan, Yuanyuan Duan, Zeng-lin Liu, Xiao-feng Lu
{"title":"积分球反射计测定633nm处黑体空腔反射率","authors":"Jing-hui Wang, Zun-dong Yuan, Yuanyuan Duan, Zeng-lin Liu, Xiao-feng Lu","doi":"10.1109/SICE.2015.7285461","DOIUrl":null,"url":null,"abstract":"The blackbody cavity emissivity is a primary parameter of blackbody source. The measurement of blackbody cavity emissivity could verify the design value of cavity emissivity. A determination of graphite blackbody cavity emissivity by reflectance measurement is presented. The measuring equipment include a He-Ne laser, laser power stabilizer, integrating sphere, Si photoelectric detector, gray reflectance standard sample and Keithley 6485 picoammeter. The preliminary measurement value of graphite blackbody cavity emissivity is 0.99983351.","PeriodicalId":405766,"journal":{"name":"Annual Conference of the Society of Instrument and Control Engineers of Japan","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of blackbody cavity reflectance at 633nm by integrating sphere reflectometer\",\"authors\":\"Jing-hui Wang, Zun-dong Yuan, Yuanyuan Duan, Zeng-lin Liu, Xiao-feng Lu\",\"doi\":\"10.1109/SICE.2015.7285461\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The blackbody cavity emissivity is a primary parameter of blackbody source. The measurement of blackbody cavity emissivity could verify the design value of cavity emissivity. A determination of graphite blackbody cavity emissivity by reflectance measurement is presented. The measuring equipment include a He-Ne laser, laser power stabilizer, integrating sphere, Si photoelectric detector, gray reflectance standard sample and Keithley 6485 picoammeter. The preliminary measurement value of graphite blackbody cavity emissivity is 0.99983351.\",\"PeriodicalId\":405766,\"journal\":{\"name\":\"Annual Conference of the Society of Instrument and Control Engineers of Japan\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-07-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annual Conference of the Society of Instrument and Control Engineers of Japan\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SICE.2015.7285461\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annual Conference of the Society of Instrument and Control Engineers of Japan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SICE.2015.7285461","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Determination of blackbody cavity reflectance at 633nm by integrating sphere reflectometer
The blackbody cavity emissivity is a primary parameter of blackbody source. The measurement of blackbody cavity emissivity could verify the design value of cavity emissivity. A determination of graphite blackbody cavity emissivity by reflectance measurement is presented. The measuring equipment include a He-Ne laser, laser power stabilizer, integrating sphere, Si photoelectric detector, gray reflectance standard sample and Keithley 6485 picoammeter. The preliminary measurement value of graphite blackbody cavity emissivity is 0.99983351.