{"title":"电压畸变和不平衡引起的感应电机热老化:使用寿命的损失及其估计成本","authors":"J. D. de Abreu, A. Emanuel","doi":"10.1109/ICPS.2001.966519","DOIUrl":null,"url":null,"abstract":"This paper reports the effect of voltage distortion and imbalance (VDI), on the thermal aging of the insulation of low voltage induction motors. The study is based on a detailed thermal modeling of actual motors in the 2 to 200 HP range. The dollar value of the useful life lost was estimated for different VDI conditions. Two important conclusions were reached: First; voltage subharmonics have a dramatic effect on motor thermal aging. Second; the overall cost of motor loss of life due to harmonic pollution and voltage imbalance, in the US today, is estimated to be in the range of 1 to 2 billion dollars per year.","PeriodicalId":383501,"journal":{"name":"2001 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record (Cat. No.01CH37226)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"144","resultStr":"{\"title\":\"Induction motor thermal aging caused by voltage distortion and imbalance: loss of useful life and its estimated cost\",\"authors\":\"J. D. de Abreu, A. Emanuel\",\"doi\":\"10.1109/ICPS.2001.966519\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper reports the effect of voltage distortion and imbalance (VDI), on the thermal aging of the insulation of low voltage induction motors. The study is based on a detailed thermal modeling of actual motors in the 2 to 200 HP range. The dollar value of the useful life lost was estimated for different VDI conditions. Two important conclusions were reached: First; voltage subharmonics have a dramatic effect on motor thermal aging. Second; the overall cost of motor loss of life due to harmonic pollution and voltage imbalance, in the US today, is estimated to be in the range of 1 to 2 billion dollars per year.\",\"PeriodicalId\":383501,\"journal\":{\"name\":\"2001 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record (Cat. No.01CH37226)\",\"volume\":\"46 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-05-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"144\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record (Cat. No.01CH37226)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPS.2001.966519\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record (Cat. No.01CH37226)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPS.2001.966519","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Induction motor thermal aging caused by voltage distortion and imbalance: loss of useful life and its estimated cost
This paper reports the effect of voltage distortion and imbalance (VDI), on the thermal aging of the insulation of low voltage induction motors. The study is based on a detailed thermal modeling of actual motors in the 2 to 200 HP range. The dollar value of the useful life lost was estimated for different VDI conditions. Two important conclusions were reached: First; voltage subharmonics have a dramatic effect on motor thermal aging. Second; the overall cost of motor loss of life due to harmonic pollution and voltage imbalance, in the US today, is estimated to be in the range of 1 to 2 billion dollars per year.