K. D. Jager, Michael Mentink, H. Lancashire, Y. Al-Ajam, Stephen Taylor, A. Vanhoestenberghe
{"title":"多通道多路肌电记录系统的特征:实现可变电极配置","authors":"K. D. Jager, Michael Mentink, H. Lancashire, Y. Al-Ajam, Stephen Taylor, A. Vanhoestenberghe","doi":"10.1109/BIOCAS.2019.8918710","DOIUrl":null,"url":null,"abstract":"An implantable EMG amplifier with a novel multiplexed frontend for in vivo selection of optimal electrode configurations, was designed using commercially available components. The multiplexers are advantageous as optimal electrode configuration are not known before implantation. The system has 6 ADC recording channels (ADS1298 biopotential amplifier, 2 kHz sampling frequency, 16-bit resolution), and three 8 × 8 multiplexer arrays (ADG2188), 2 channels per MUX. The system was characterised by measuring input impedance (5.8 MOhm) and frequency response (CMRR 49.0 dB; SNR 51.4 dB). EMG recordings from implanted epimysial electrodes showed lower signal quality (13.5 dB) compared with a commercial EMG recorder (19.5 dB), nonetheless the signals appeared suitable for myoelectric control applications. An implantable version of the EMG recorder, housed within a hermetically sealed ceramic package, should improve signal quality.","PeriodicalId":222264,"journal":{"name":"2019 IEEE Biomedical Circuits and Systems Conference (BioCAS)","volume":"332 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Characterisation of a multi-channel multiplexed EMG recording system: towards realising variable electrode configurations\",\"authors\":\"K. D. Jager, Michael Mentink, H. Lancashire, Y. Al-Ajam, Stephen Taylor, A. Vanhoestenberghe\",\"doi\":\"10.1109/BIOCAS.2019.8918710\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An implantable EMG amplifier with a novel multiplexed frontend for in vivo selection of optimal electrode configurations, was designed using commercially available components. The multiplexers are advantageous as optimal electrode configuration are not known before implantation. The system has 6 ADC recording channels (ADS1298 biopotential amplifier, 2 kHz sampling frequency, 16-bit resolution), and three 8 × 8 multiplexer arrays (ADG2188), 2 channels per MUX. The system was characterised by measuring input impedance (5.8 MOhm) and frequency response (CMRR 49.0 dB; SNR 51.4 dB). EMG recordings from implanted epimysial electrodes showed lower signal quality (13.5 dB) compared with a commercial EMG recorder (19.5 dB), nonetheless the signals appeared suitable for myoelectric control applications. An implantable version of the EMG recorder, housed within a hermetically sealed ceramic package, should improve signal quality.\",\"PeriodicalId\":222264,\"journal\":{\"name\":\"2019 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"volume\":\"332 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIOCAS.2019.8918710\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Biomedical Circuits and Systems Conference (BioCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOCAS.2019.8918710","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

设计了一种可植入的EMG放大器,该放大器具有新颖的多路复用前端,用于在体内选择最佳电极配置。多路复用器是有利的,因为在植入前不知道最佳电极配置。该系统具有6个ADC记录通道(ADS1298生物电位放大器,2 kHz采样频率,16位分辨率)和3个8 × 8多路复用器阵列(ADG2188),每个MUX有2个通道。测试了系统的输入阻抗(5.8 MOhm)和频率响应(CMRR 49.0 dB;信噪比51.4 dB)。植入的外膜电极的肌电信号记录显示,与商用肌电信号记录器(19.5 dB)相比,信号质量(13.5 dB)较低,尽管如此,信号似乎适合于肌电控制应用。一种植入式的肌电记录仪,安装在一个密封的陶瓷封装内,应该可以改善信号质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Characterisation of a multi-channel multiplexed EMG recording system: towards realising variable electrode configurations
An implantable EMG amplifier with a novel multiplexed frontend for in vivo selection of optimal electrode configurations, was designed using commercially available components. The multiplexers are advantageous as optimal electrode configuration are not known before implantation. The system has 6 ADC recording channels (ADS1298 biopotential amplifier, 2 kHz sampling frequency, 16-bit resolution), and three 8 × 8 multiplexer arrays (ADG2188), 2 channels per MUX. The system was characterised by measuring input impedance (5.8 MOhm) and frequency response (CMRR 49.0 dB; SNR 51.4 dB). EMG recordings from implanted epimysial electrodes showed lower signal quality (13.5 dB) compared with a commercial EMG recorder (19.5 dB), nonetheless the signals appeared suitable for myoelectric control applications. An implantable version of the EMG recorder, housed within a hermetically sealed ceramic package, should improve signal quality.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信