{"title":"一种适用于可穿戴传感器的535nW/通道无损数据压缩的ECG-SoC","authors":"Deepu John","doi":"10.1109/ASSCC.2013.6691003","DOIUrl":null,"url":null,"abstract":"This paper presents a low power ECG recording Sys-tem-on-Chip (SoC) with on-chip low complexity lossless ECG compression for data reduction in wireless/ambulatory ECG sensor devices. The proposed algorithm uses a linear slope predictor to estimate the ECG samples, and uses a novel low complexity dynamic coding-packaging scheme to frame the resulting estimation error into fixed-length 16-bit format. The proposed technique achieves an average compression ratio of 2.25× on MIT/BIH ECG database. Implemented in 0.35 μm process, the compressor uses 0.565 K gates/channel occupying 0.4 mm2 for 4-channel, and consumes 535 nW/channel at 2.4V for ECG sampled at 512 Hz. Small size and ultra-low power consumption makes the proposed technique suitable for wearable ECG sensor application.","PeriodicalId":296544,"journal":{"name":"2013 IEEE Asian Solid-State Circuits Conference (A-SSCC)","volume":"67 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"An ECG-SoC with 535nW/channel lossless data compression for wearable sensors\",\"authors\":\"Deepu John\",\"doi\":\"10.1109/ASSCC.2013.6691003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a low power ECG recording Sys-tem-on-Chip (SoC) with on-chip low complexity lossless ECG compression for data reduction in wireless/ambulatory ECG sensor devices. The proposed algorithm uses a linear slope predictor to estimate the ECG samples, and uses a novel low complexity dynamic coding-packaging scheme to frame the resulting estimation error into fixed-length 16-bit format. The proposed technique achieves an average compression ratio of 2.25× on MIT/BIH ECG database. Implemented in 0.35 μm process, the compressor uses 0.565 K gates/channel occupying 0.4 mm2 for 4-channel, and consumes 535 nW/channel at 2.4V for ECG sampled at 512 Hz. Small size and ultra-low power consumption makes the proposed technique suitable for wearable ECG sensor application.\",\"PeriodicalId\":296544,\"journal\":{\"name\":\"2013 IEEE Asian Solid-State Circuits Conference (A-SSCC)\",\"volume\":\"67 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE Asian Solid-State Circuits Conference (A-SSCC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ASSCC.2013.6691003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Asian Solid-State Circuits Conference (A-SSCC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASSCC.2013.6691003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

摘要

本文提出了一种低功耗的心电记录片上系统(SoC),该系统具有片上低复杂度的无损心电压缩功能,可用于无线/动态心电传感器设备的数据压缩。该算法采用线性斜率预测器对心电信号样本进行估计,并采用一种新颖的低复杂度动态编码封装方案将估计误差压缩成固定长度的16位格式。该方法在MIT/BIH心电数据库上实现了2.25倍的平均压缩比。该压缩机采用0.35 μm工艺,4通道使用0.565 K门/通道,占用0.4 mm2,在2.4V下采样512 Hz的ECG时消耗535 nW/通道。该技术体积小,功耗极低,适用于可穿戴式心电传感器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An ECG-SoC with 535nW/channel lossless data compression for wearable sensors
This paper presents a low power ECG recording Sys-tem-on-Chip (SoC) with on-chip low complexity lossless ECG compression for data reduction in wireless/ambulatory ECG sensor devices. The proposed algorithm uses a linear slope predictor to estimate the ECG samples, and uses a novel low complexity dynamic coding-packaging scheme to frame the resulting estimation error into fixed-length 16-bit format. The proposed technique achieves an average compression ratio of 2.25× on MIT/BIH ECG database. Implemented in 0.35 μm process, the compressor uses 0.565 K gates/channel occupying 0.4 mm2 for 4-channel, and consumes 535 nW/channel at 2.4V for ECG sampled at 512 Hz. Small size and ultra-low power consumption makes the proposed technique suitable for wearable ECG sensor application.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信