{"title":"高压直流变换器端子附近电场和磁场对植入心脏起搏器的影响","authors":"M. Frazier","doi":"10.1109/ISEMC.1979.7568847","DOIUrl":null,"url":null,"abstract":"The electromagnetic fields associated with HVDC converters and transmission lines constitute a unique environment for persons with implanted cardiac pacemakers. A measurement program has been conducted to assess the potential interfering effects of these harmonically rich fields on implanted pacemakers. The experimental procedures that were employed take into account the combined effects of the electric and magnetic fields. The effect of the resulting body current on the response of six pacemakers was assessed in the laboratory, using a previously developed model to relate body current to pacemaker pickup voltage. The results show that R-wave pacemaker reversion can be expected at some locations within the converter facility, but that a large safety margin for unperturbed pacemaker operation exists beneath the transmission lines.","PeriodicalId":283257,"journal":{"name":"1979 IEEE International Symposium on Electromagnetic Compatibility","volume":"413 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1979-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Effect of Electric and Magnetic Fields Near HVDC Converter Terminal on Implanted Cardiac Pacemakers\",\"authors\":\"M. Frazier\",\"doi\":\"10.1109/ISEMC.1979.7568847\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The electromagnetic fields associated with HVDC converters and transmission lines constitute a unique environment for persons with implanted cardiac pacemakers. A measurement program has been conducted to assess the potential interfering effects of these harmonically rich fields on implanted pacemakers. The experimental procedures that were employed take into account the combined effects of the electric and magnetic fields. The effect of the resulting body current on the response of six pacemakers was assessed in the laboratory, using a previously developed model to relate body current to pacemaker pickup voltage. The results show that R-wave pacemaker reversion can be expected at some locations within the converter facility, but that a large safety margin for unperturbed pacemaker operation exists beneath the transmission lines.\",\"PeriodicalId\":283257,\"journal\":{\"name\":\"1979 IEEE International Symposium on Electromagnetic Compatibility\",\"volume\":\"413 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1979-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1979 IEEE International Symposium on Electromagnetic Compatibility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.1979.7568847\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1979 IEEE International Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.1979.7568847","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

与高压直流变流器和传输线相关的电磁场构成了植入心脏起搏器的人的独特环境。一个测量程序被用来评估这些谐波丰富的场对植入心脏起搏器的潜在干扰效应。所采用的实验程序考虑到了电场和磁场的综合作用。在实验室中,使用先前开发的将身体电流与起搏器拾取电压联系起来的模型,评估了产生的身体电流对六个起搏器响应的影响。结果表明,在变流器设施的某些位置可以预期r波起搏器的反转,但在输电线路下存在较大的无扰动起搏器运行的安全余量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Effect of Electric and Magnetic Fields Near HVDC Converter Terminal on Implanted Cardiac Pacemakers
The electromagnetic fields associated with HVDC converters and transmission lines constitute a unique environment for persons with implanted cardiac pacemakers. A measurement program has been conducted to assess the potential interfering effects of these harmonically rich fields on implanted pacemakers. The experimental procedures that were employed take into account the combined effects of the electric and magnetic fields. The effect of the resulting body current on the response of six pacemakers was assessed in the laboratory, using a previously developed model to relate body current to pacemaker pickup voltage. The results show that R-wave pacemaker reversion can be expected at some locations within the converter facility, but that a large safety margin for unperturbed pacemaker operation exists beneath the transmission lines.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信